A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Visualization of the microtubules of glutaraldehyde-fixed cells by reflection-enhanced backscatter confocal microscopy. | LitMetric

Visualization of the microtubules of glutaraldehyde-fixed cells by reflection-enhanced backscatter confocal microscopy.

Microsc Microanal

Department of Cellular Biology, The University of Georgia, 724 Biological Sciences Building, Athens, GA 30602, USA.

Published: April 2006

Performing reflection-mode (backscatter-mode) confocal microscopy on cells growing on reflective substrates gives images that have improved contrast and are more easily interpreted than standard reflection-mode confocal micrographs (Keith et al., 1998). However, a number of factors degrade the quality of images taken with the highest-resolution microscope objectives in this technique. We here describe modifications to reflection-enhanced backscatter confocal microscopy that (partially) overcome these factors. With these modifications of the technique, it is possible to visualize structures the size-and refractility-of individual microtubules in intact cells. Additionally, we demonstrate that this technique, in common with fluorescence techniques such as standing wave widefield fluorescence microscopy and 4-Pi confocal microscopy, offers improved resolution in the Z-direction.

Download full-text PDF

Source
http://dx.doi.org/10.1017/S1431927606060016DOI Listing

Publication Analysis

Top Keywords

confocal microscopy
16
reflection-enhanced backscatter
8
backscatter confocal
8
confocal
5
microscopy
5
visualization microtubules
4
microtubules glutaraldehyde-fixed
4
glutaraldehyde-fixed cells
4
cells reflection-enhanced
4
microscopy performing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!