Objective: Spirometry-based screening programmes often conduct annual assessment of longitudinal changes in forced expiratory volume in 1 second (FEV1) to identify individuals with excessive rates of decline. Both the American Thoracic Society (ATS) and the American College of Occupational and Environmental Medicine (ACOEM) recommend a reference limit value of > or =15% for excessive annual decline. Neither the ATS nor the ACOEM adjust this limit for the precision of the existing spirometry data. The authors propose an improved method of defining the reference limit of longitudinal annual FEV1 decline (LLD) based on the precision of the spirometry data.
Method: The authors used data from four monitoring programmes and measured their data precision using a pair-wise within-person variation statistic. They then derived programme- and gender-specific absolute and relative LLD values and validated these against the 95th percentiles for observed yearly changes in FEV1.
Results: The relative limit for annual decline was more practical than the absolute limit as it adjusted for gender differences in the magnitude of FEV1. The programme-specific relative limit values were in good agreement with 95th percentiles for year-to-year FEV1 changes and ranged from 6.6% to 15.8%. For individuals with COPD and bronchial hyperreactivity the 95th percentiles for year-to-year changes were about 15% and higher.
Conclusions: The relative longitudinal limit for annual FEV1 decline based upon precision of measurements is valid and can be generalised to different gender and population groups. A relative limit of approximately 10% appears appropriate for good quality workplace monitoring programmes, whereas a limit of about 15% appears appropriate for clinical evaluation of individuals with an obstructive airway disease. Computer software based on the method described is available from the corresponding author.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2078388 | PMC |
http://dx.doi.org/10.1136/oem.2006.031146 | DOI Listing |
Medicine (Baltimore)
November 2024
Department of Cardiology, The First Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang, Hunan, China.
Hyperhomocysteinemia (serum homocysteine concentration > 15 μmol/L) is of high prevalence in chronic kidney disease (CKD). And myocardial hypertrophy is a common complication of CKD. Given that both hyperhomocysteinemia and cardiac hypertrophy have an association with CKD, we hypothesized that high level of plasma homocysteine (Hcy) is associated with a higher prevalence of ventricular hypertrophy(LVH) in adults with CKD.
View Article and Find Full Text PDFJ Pediatr Gastroenterol Nutr
January 2025
Department of Epidemiology and Biostatistics, Jiann-Ping Hsu College of Public Health, Georgia Southern University, Statesboro, Georgia, USA.
Objectives: The trend of alanine aminotransferase (ALT), a biomarker of metabolic dysfunction-associated steatotic liver disease (MASLD, formerly known as nonalcoholic fatty liver disease), remains poorly described for the pediatric population because no widely accepted cutoffs are available to categorize ALT value. We described the nuanced changes in the distribution of ALT continuous values.
Study Design: We analyzed the data from 15,702 adolescents aged 12-19 who participated in the National Health and Nutrition Examination Surveys between 1988 and 2020.
Phys Imaging Radiat Oncol
October 2024
Université Paris-Saclay, Gustave Roussy, Inserm, Molecular Radiotherapy and Therapeutic Innovation, U1030, 94800 Villejuif, France.
Background And Purpose: Deep-learning-based automatic segmentation is widely used in radiation oncology to delineate organs-at-risk. Dual-energy CT (DECT) allows the reconstruction of enhanced contrast images that could help with manual and auto-delineation. This paper presents a performance evaluation of a commercial auto-segmentation software on image series generated by a DECT.
View Article and Find Full Text PDFPhys Imaging Radiat Oncol
January 2025
Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands.
Background And Purpose: A novel ring-gantry cone-beam computed tomography (CBCT) imaging system shows improved image quality compared to its conventional version, but its effect on autosegmentation is unknown. This study evaluates the impact of this high-performance CBCT on autosegmentation performance, inter-observer variability, contour correction times and delineation confidence, compared to the conventional CBCT.
Materials And Methods: Twenty prostate cancer patients were enrolled in this prospective clinical study.
Heliyon
January 2025
Health and Environment Research Center, Ilam University of Medical Sciences, Ilam, Iran.
Food toxicity through heavy metals, particularly from cereal consumption, poses significant threats to human health. This study studied various toxic heavy metals (Pb, As, Cr, Cd, Co, Hg, and Ag) in cereal products and their human health risk assessment in Ilam province, Iran. This study analyzed 30 samples of the most commonly cultivated cereals (wheat, rice, corn, pea, and lentil) in Ilam province.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!