According to the World Health Organization (WHO), indoor air pollution (IAP) from the use of solid fuels in households in the developing world is responsible for more than 1.6 million premature deaths each year, whereof 0.42 million occur in China alone. We argue that the methodology applied by WHO--the so-called fuel-based approach--underestimates the health effects, and suggest an alternative method. Combining exposure-response functions and current mortality and morbidity rates, we estimate the burden of disease of IAP in China and the impacts of three abatement scenarios. Using linear exposure-response functions, we find that 3.5 [0.8-14.7 95% CI] million people die prematurely due to IAP in China each year. The central estimate constitutes 47% of all deaths in China. We find that modest changes in the use of cooking fuels in rural households might have a large health impact, reducing annual mortality by 0.63 [0.1-3. 2 95% CI] million. If the indoor air quality (IAQ) standard set by the Chinese government (150 microg PM(10)/m(3)) was met in all households, we estimate that 0.9 [0.2-4.8] million premature deaths would be avoided in urban areas and 2.8 [0.7-12.4] million in rural areas. However, in urban areas this would require improvements to the outdoor air quality in addition to a complete fuel switch to clean fuels in households. We estimate that a fuel switch in urban China could prevent 0.7 [0.2-4.8] million premature deaths. The methodology for exposure assessment applied here is probably more realistic than the fuel-based approach; however, the use of linear exposure-response relationships most likely tends to overestimate the effects. The discrepancies between our results and the WHO estimates is probably also explained by our use of "all-cause mortality" which includes important causes of death like cardiovascular diseases, conditions known to be closely associated with exposure to particulate pollution, whereas the WHO estimate is limited to respiratory diseases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.envint.2007.03.012DOI Listing

Publication Analysis

Top Keywords

indoor air
12
premature deaths
12
air pollution
8
abatement scenarios
8
fuels households
8
exposure-response functions
8
iap china
8
linear exposure-response
8
95% ci]
8
air quality
8

Similar Publications

Interest in carbon dioxide (CO) sensors is growing rapidly due to the increasing awareness of the link between air quality and health. Indoor, high CO levels signal poor ventilation, and outdoor the burning of fossil fuels and its associated pollution. CO gas sensors based on integrated optical waveguides are a promising solution due to their excellent gas sensing selectivity, compact size, and potential for mass manufacturing large volumes at low cost.

View Article and Find Full Text PDF

Formaldehyde is considered as a significant contaminant. This study aimed to perform comprehensive research with systematic review, health risk estimation, meta-analysis, and Monte Carlo simulation to evaluate exposure to formaldehyde at different seasons of the year in various indoor environments. A systematic literature review was initially performed.

View Article and Find Full Text PDF

Purpose Of Review: A major contributor to household air pollution (HAP) in sub-Saharan Africa (SSA) is unclean cooking fuel. Improved cookstove technology (ICT) interventions have been promoted as a solution, but their impacts on health are unclear. Our aim is to conduct a systematic review to explore the impacts of ICT interventions on health outcomes in SSA.

View Article and Find Full Text PDF

Background: Air pollution is associated with poor asthma outcomes in children. However, most studies focus on ambient or indoor monitor pollution levels. Few studies evaluate breathing zone exposures, which may be more consequential for asthma outcomes.

View Article and Find Full Text PDF

We evaluated enterocyte damage (IFABP), microbial translocation (sCD14), and inflammatory responses (TNF-α, IL-6, CRP) in 16 older adults (66-78 years) during 8 hours rest in conditions simulating homes maintained at 22°C (control), the 26°C indoor temperature upper limit proposed by health agencies, and homes without air-conditioning during heatwaves (31°C, 36°C). Relative to 22°C, IFABP was elevated ~181 pg/mL after exposure to 31°C (P=0.07), and by ~378 pg/mL (P<0.

View Article and Find Full Text PDF