A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid and high-resolution detection of IgH gene rearrangements using PCR and melting curve analysis. | LitMetric

Rapid and high-resolution detection of IgH gene rearrangements using PCR and melting curve analysis.

Int J Lab Hematol

Department of Laboratory Medicine, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki University Hospital, Nagasaki City, Nagasaki, Japan.

Published: June 2007

The analytical methods of Southern blot hybridization (SBH) and the polymerase chain reaction (PCR) for complementarity determining region-3 (CDR3) are fundamental for detecting IgH gene rearrangement. However, there are problems stemming from the characteristics of both methods; especially, the long turn around time (TAT) because of the complex process in the SBH, and the low analytical sensitivity for amplicons in the PCR. Thus, to improve the PCR procedure, we investigated the application of detecting the clonal amplicons based on the different melting Temperature (T(m)) in internal melting domains corresponding to the CDR3 hypervariable region. Our new protocol is based on the combination of a LightCycler Technology with high-speed amplification, and Idaho-Technology with rapid and high-resolution melting curve analysis (MCA), designated PCR-MCA. This method can provide the results within 3 h with an analytical sensitivity of 10(-3). The diagnostic sensitivity and specificity relative to the results documented with the SBH analysis were 89.2% and 100%, respectively. This indicates that the new protocol of PCR-MCA is acceptable for clinical testing; especially, PCR-MCA is relevant in terms of the rapid and sensitive detection of IgH clonality within amplicons.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1751-553X.2006.00832.xDOI Listing

Publication Analysis

Top Keywords

rapid high-resolution
8
detection igh
8
igh gene
8
melting curve
8
curve analysis
8
analytical sensitivity
8
high-resolution detection
4
gene rearrangements
4
pcr
4
rearrangements pcr
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!