A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dose effects of cross-linking polyethylene for total knee arthroplasty on wear performance and mechanical properties. | LitMetric

Wear performance and mechanical properties of cross-linking polyethylene (XLPE) tibial inserts were investigated using a knee simulator, scanning electron microscopy (SEM), and a small punch test (SPT). Ultrahigh molecular weight PE made from GUR1050 resin was irradiated at doses ranging from 0 to 200 kGy and then machined into tibial inserts followed by annealing. The knee simulator was run for up to four million cycles. As the radiation dose increased from 0 to 100 kGy, the wear rate decreased dramatically, yielding 95% wear reduction at 100 kGy. The microwear features observed by SEM supported the dose-dependent wear reduction. The SPT for XLPE after the simulation test showed that, as the radiation dose increased from 0 to 200 kGy, the ultimate displacement decreased dose-dependently, while the ultimate load increased from 0 to 75 kGy and decreased from 75 to 200 kGy. The resulting toughness of the PE increased to its maximum at a dose of 50 kGy and then decreased with higher doses up to 200 kGy. PE cross-linked with radiation doses from 25 to 75 kGy had greater toughness than virgin, nonirradiated PE. However, PE irradiated with 100 kGy or more had lower toughness than virgin PE. These data suggest that a certain amount of irradiation enhances both wear performance and toughness of PE tibial inserts. Although a certain amount of cross-linking would be effective for clinical application of PE tibial inserts, an optimal radiation dose should be much smaller than that used in current XLPE in total hip arthroplasty.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.30835DOI Listing

Publication Analysis

Top Keywords

tibial inserts
16
200 kgy
16
wear performance
12
radiation dose
12
100 kgy
12
kgy
10
cross-linking polyethylene
8
performance mechanical
8
mechanical properties
8
knee simulator
8