A pulsatile flow phantom was developed for studies of ultrasound image-guided high intensity focused ultrasound (HIFU) application in transcutaneous hemostasis of injured blood vessels. The flow phantom consisted of a pulsatile pump system with instrumented excised porcine carotid artery, which was imbedded in a transparent agarose gel to model structural configuration of in vivo tissues. Heparinized porcine blood was circulated through the phantom. The artery was injured using an 18-gauge needle to model a penetrating injury in human peripheral vasculature. A HIFU transducer with the diameter of 7 cm, focal length of 6.3 cm and frequency of 3.4 MHz was used to seal the puncture. Ultrasound imaging was used to localize and target the puncture site and to monitor the HIFU treatment. Triphasic blood flows present in the human arteries were reproduced, with flow rates of 50 to 500 mL/min, pulse rates of 62 to 138 beats/min and peak pressures of 100 to 250 mm Hg. The penetrating injury of an artery was mimicked successfully in the flow phantom setting and was easily visualized both optically through the transparent gel and with power Doppler ultrasound imaging. Hemostasis was achieved in 55 +/- 31 s (n = 9) of HIFU application. Histologic observations showed that a HIFU-sealed puncture was filled with clotted blood and covered with a fibrin cap. The pulsatile flow phantom provides a controlled and repeatable environment for studies of transcutaneous image-guided HIFU application in hemostasis of a variety of blood vessel injuries.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2692665 | PMC |
http://dx.doi.org/10.1016/j.ultrasmedbio.2007.02.011 | DOI Listing |
NMR Biomed
March 2025
Centre for Advanced Imaging, The University of Queensland, St Lucia, Queensland, Australia.
In this work, we introduce spatial and chemical saturation options for artefact reduction in magnetic resonance fingerprinting (MRF) and assess their impact on T and T mapping accuracy. An existing radial MRF pulse sequence was modified to enable spatial and chemical saturation. Phantom experiments were performed to demonstrate flow artefact reduction and evaluate the accuracy of the T and T maps.
View Article and Find Full Text PDFMethodsX
June 2025
Texas A&M University Department of Biomedical Engineering, College Station, TX 77840, US.
Physical anatomical models constructed from medical images are valuable research tools for evaluating patient-specific clinical circumstances. For example, 3D models replicating a patient's internal anatomy in the cardiovascular system can be used to validate Computational Fluid Dynamics (CFD) models, which can then be used to identify potential hemodynamic consequences of surgical decisions by providing insight into how blood and vascular tissue mechanics may contribute to disease progression and post-operative complications. Patient-specific models have been described in the literature; however, rapid prototyping models that achieve anatomical accuracy, optical transparency, and thin-walled compliance in a cost and time-effective approach have proven challenging.
View Article and Find Full Text PDFJ Magn Reson Imaging
January 2025
Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden.
Background: Real-time (RT) phase contrast (PC) flow MRI can potentially be used to measure blood flow in arrhythmic patients. Undersampled RT PC has been combined with online compressed sensing (CS) reconstruction (CS RT) enabling clinical use. However, CS RT flow has not been validated in a clinical setting.
View Article and Find Full Text PDFJ Biophotonics
January 2025
Department of Emergency, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China.
The brain, as a vital part of central nervous system, receives approximately 25% of body's blood supply, making accurate monitoring of cerebral blood flow essential. While fNIRS is widely used for measuring brain physiology, complex tissue structure affects light intensity, spot size, and detection accuracy. Many studies rely on simulations with limited experimental validation.
View Article and Find Full Text PDFJACC Case Rep
January 2025
Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Anomalous aortic origin of coronary artery can lead to ischemia. Due to the limitations of invasive catheterization dobutamine stress testing, an alternative noninvasive approach is desired. A 65-year-old woman with atypical chest pain was referred for coronary computed tomography angiography.