Purpose: Mandibular deformation during function in patients with implant-supported prostheses is associated with increased strain at the bone-implant interface when dental implants are connected by a relatively rigid superstructure. Whilst there is a body of evidence concerning deformation as measured between the corpora, there are little data on its effects in the midline. This study measured 3 types of midline mandibular deformation during nonmasticatory functional mandibular movements in edentulous subjects with dental implants.
Materials And Methods: A range of custom displacement transducers was fabricated for 5 edentulous subjects who had been treated with dental implants in the anterior mandible. These transducers were mounted on contralateral implant abutments adjacent to the midline to measure medial convergence, corporal rotation, and anteroposterior shear. Their output was recorded for offline analysis by a personal computer.
Results: The values of medial convergence ranged from 15 to 42 microm during opening, from 10 to 21 microm during lateral excursions, and from 18 to 53 microm during protrusion. Corporal rotation varied from 0.05 to 0.11 degrees during opening, from 0.03 to 0.08 degrees during lateral excursions, and from 0.03 to 0.15 degrees during protrusion. Anteroposterior shear varied from 38 to 93 pm during opening, from 28 to 56 microm during lateral excursions, and from 52 to 103 pm during protrusion.
Discussion And Conclusions: Nonmasticatory physiological mandibular movements cause the jaw to deform about the midline in at least 3 directions. It is important for the clinician to be aware of the phenomenon of mandibular deformation, which should be taken into consideration in the design and monitoring of mandibular prostheses.
Download full-text PDF |
Source |
---|
Cureus
November 2024
Department of Removable Prosthodontics, Syrian Arab Republic Damascus University Faculty of Dental Medicine, Damascus, SYR.
Background: Determining the distal cantilever length in All-on-Four (All-on-4) implant-supported prostheses is a major factor in the long-term success of these prostheses. The difference in mechanical properties of materials used in the fabrication of these prostheses, such as polyether ether ketone (PEEK), may have an impact on the determination of the cantilever length that best distributes stress.
Aim: To study the distribution of stress in All-on-4 mandibular prostheses in the bone, implants, and framework according to difference cantilever length in PEEK prosthetic framework using three-dimensional finite element analysis.
Clin Oral Investig
December 2024
Hospital of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, 510055, China.
Objectives: To compare the variations in the upper airway of children with skeletal Class II mandibular retrognathism treated with van Beek Headgear-Activator (vBHGA) and Twin-Block (TB) appliances.
Materials And Methods: 40 children were involved in this retrospective study and divided into two intervention groups: the vBHGA group and the TB group, each comprising 20 individuals with an average age of 11.13 years.
J Craniofac Surg
October 2024
State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Center of Orthognathic and TMJ Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan.
Skeletal Class III malocclusion deformity is one of the most common maxillofacial malocclusions in East Asia and is either due to maxillary retrusion, mandibular protrusion, or both. It could cause functional and aesthetic problems. This deformity could be attributed to either hereditary or environmental factors or both.
View Article and Find Full Text PDFJ Med Life
October 2024
Department of Removable Prosthodontics, Faculty of Dental Medicine, University of Monastir, Monastir, Tunisia.
Amelogenesis imperfecta refers to a group of hereditary diseases that affect dental enamel, often leading to a wide range of clinical manifestations and aesthetic concerns. This case report describes a female patient diagnosed with amelogenesis imperfecta associated with a skeletal open bite. The treatment approach was multidisciplinary.
View Article and Find Full Text PDFEur J Med Res
December 2024
Urumql DW Innovation InfoTech Co., Ltd., Xinjiang, China.
Objective: The primary focus of this investigation was to evaluate the biomechanical effects of high trimline design aligners on the distalization of mandibular molars, employing three-dimensional finite element analysis (3D-FEA). The study concentrated on aspects such as tooth movement, stress distribution, and anchorage control.
Methods: Utilizing Cone-beam computed tomography (CBCT) data, a detailed 3D geometrical model was constructed for finite element analysis.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!