The dilemma of ICD implant testing.

Pacing Clin Electrophysiol

Division of Cardiology, Department of Medicine, Cedars-Sinai Medical Center, and the David Geffen School of Medicine, UCLA, Los Angeles, California, USA.

Published: May 2007

Ventricular fibrillation (VF) has been induced at implantable cardioverter defibrillator (ICD) implant to ensure reliable sensing, detection, and defibrillation. Despite its risks, the value was self-evident for early ICDs: failure of defibrillation was common, recipients had a high risk of ventricular tachycardia (VT) or VF, and the only therapy for rapid VT or VF was a shock. Today, failure of defibrillation is rare, the risk of VT/VF is lower in some recipients, antitachycardia pacing is applied for fast VT, and vulnerability testing permits assessment of defibrillation efficacy without inducing VF in most patients. This review reappraises ICD implant testing. At implant, defibrillation success is influenced by both predictable and unpredictable factors, including those related to the patient, ICD system, drugs, and complications. For left pectoral implants of high-output ICDs, the probability of passing a 10 J safety margin is approximately 95%, the probability that a maximum output shock will defibrillate is approximately 99%, and the incidence of system revision based on testing is < or = 5%. Bayes' Theorem predicts that implant testing identifies < or = 50% of patients at high risk for unsuccessful defibrillation. Most patients who fail implant criteria have false negative tests and may undergo unnecessary revision of their ICD systems. The first-shock success rate for spontaneous VT/VF ranges from 83% to 93%, lower than that for induced VF. Thus, shocks for spontaneous VT/VF fail for reasons that are not evaluated at implant. Whether system revision based on implant testing improves this success rate is unknown. The risks of implant testing include those related to VF and those related to shocks alone. The former may be due to circulatory arrest alone or the combination of circulatory arrest and shocks. Vulnerability testing reduces risks related to VF, but not those related to shocks. Mortality from implant testing probably is 0.1-0.2%. Overall, VF should be induced to assess sensing in approximately 5% of ICD recipients. Defibrillation or vulnerability testing is indicated in 20-40% of recipients who can be identified as having a higher-than-usual probability of an inadequate defibrillation safety margin based on patient-specific factors. However, implant testing is too risky in approximately 5% of recipients and may not be worth the risks in 10-30%. In 25-50% of ICD recipients, testing cannot be identified as either critical or contraindicated.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8159.2007.00730.xDOI Listing

Publication Analysis

Top Keywords

implant testing
28
icd implant
12
testing
12
vulnerability testing
12
implant
11
defibrillation
8
failure defibrillation
8
high risk
8
safety margin
8
system revision
8

Similar Publications

In current study, microstructural, mechanical and corrosion behaviour were investigated with incorporation of dual reinforced AZ91D surface composites. This research was carried out for enhancement of the bio-degradability in biological environment. The surface composites were successfully fabricated by friction stir processing method with a rotation speed of 800 rpm, travel speed of 80 mm/min and 2.

View Article and Find Full Text PDF

Human epidermal growth factor receptor 2 (HER2, also known as ERBB2) signaling promotes cell growth and differentiation, and is overexpressed in several tumor types, including breast, gastric and colorectal cancer. HER2-targeted therapies have shown clinical activity against these tumor types, resulting in regulatory approvals. However, the efficacy of HER2 therapies in tumors with HER2 mutations has not been widely investigated.

View Article and Find Full Text PDF

Anaerobic Adhesive Effect on the Counter-Torque of Zirconia Implant Abutment Screws: In Vitro Study.

Clin Implant Dent Relat Res

February 2025

Department of Restorative Dentistry, Faculty of Dentistry, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil.

Introduction: Implantology has become a primary solution for tooth loss due to excellent osseointegration and high long-term success rates. However, complications such as abutment screw loosening, especially in implant-supported single crowns, compromise prosthesis longevity. Anaerobic adhesives (AAs) have shown promise in mechanical fields for preventing screw loosening, but their effectiveness in dental implants, particularly zirconia, remains uncertain.

View Article and Find Full Text PDF

Implantable drug delivery systems are crucial for achieving sustained delivery of active compounds to specific sites or systemic circulation. In this study, a novel reservoir-type implant combining a biodegradable rate-controlling membrane with a drug-containing core prepared using direct compression techniques is developed. The membrane is composed of poly(caprolactone) (PCL), and risperidone (RIS) served as the model drug.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!