Purpose: To develop a consensus standard for quantification of coronary artery calcium (CAC).

Materials And Methods: A standard for CAC quantification was developed by a multi-institutional, multimanufacturer international consortium of cardiac radiologists, medical physicists, and industry representatives. This report specifically describes the standardization of scan acquisition and reconstruction parameters, the use of patient size-specific tube current values to achieve a prescribed image noise, and the use of the calcium mass score to eliminate scanner- and patient size-based variations. An anthropomorphic phantom containing calibration inserts and additional phantom rings were used to simulate small, medium-size, and large patients. The three phantoms were scanned by using the recommended protocols for various computed tomography (CT) systems to determine the calibration factors that relate measured CT numbers to calcium hydroxyapatite density and to determine the tube current values that yield comparable noise values. Calculation of the calcium mass score was standardized, and the variance in Agatston, volume, and mass scores was compared among CT systems.

Results: Use of the recommended scanning parameters resulted in similar noise for small, medium-size, and large phantoms with all multi-detector row CT scanners. Volume scores had greater interscanner variance than did Agatston and calcium mass scores. Use of a fixed calcium hydroxyapatite density threshold (100 mg/cm(3)), as compared with use of a fixed CT number threshold (130 HU), reduced interscanner variability in Agatston and calcium mass scores. With use of a density segmentation threshold, the calcium mass score had the smallest variance as a function of patient size.

Conclusion: Standardized quantification of CAC yielded comparable image noise, spatial resolution, and mass scores among different patient sizes and different CT systems and facilitated reduced radiation dose for small and medium-size patients.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2432050808DOI Listing

Publication Analysis

Top Keywords

calcium mass
20
mass scores
16
mass score
12
small medium-size
12
calcium
9
coronary artery
8
artery calcium
8
multi-institutional multimanufacturer
8
multimanufacturer international
8
standard quantification
8

Similar Publications

Background: Radioactive iodine (RAI) is a common treatment for various thyroid diseases. Previous studies have suggested susceptibility of parathyroid glands to the mutagenic effect of RAI and the development of primary hyperparathyroidism (PHPT). We tested the possible link between prior RAI treatment, disease presentation, and treatment outcomes.

View Article and Find Full Text PDF

Unlabelled: Non tuberculous mycobacteria (NTM) are important opportunistic infection in patients with AIDS.

Aim: To present 4 cases of disseminated infections by NTM in patients with AIDS.

Results: These cases were associated with prolonged symptoms of fever, weight loss, diarrhea or cough, with hepatosplenomegaly, anemia and thrombocytopenia.

View Article and Find Full Text PDF

Background: In patients with chronic kidney disease (CKD), trimethylamine n-oxide (TMAO) accumulation exacerbates inflammation and contributes to oxidative stress. These complications are putatively linked to the development of cardiovascular diseases. Despite the known associations, the variation in TMAO plasma levels across different CKD stages and dialysis modalities remains underexplored.

View Article and Find Full Text PDF

Traditional pulp-capping materials like mineral trioxide aggregate (MTA) offer excellent biocompatibility and sealing, but limitations such as prolonged setting time, low bioactivity, and high costs persist. Metformin, with its potential in craniofacial regeneration, could enhance dentin synthesis by targeting pulp cells. This study aimed to: (1) develop a calcium phosphate cement with chitosan (CPCC) with improved physio-mechanical properties; (2) incorporate metformin (CPCC-Met) to assess release; and (3) evaluate human dental pulp stem cells (hDPSCs) response.

View Article and Find Full Text PDF

The study aimed to investigate the stability and anti-allergic efficacy of phycocyanin through the construction of microcapsules. Phycocyanin (PC), a blue pigment found in microalgae, has attracted significant attention due to its anti-allergic properties. However, it is susceptible to instability when exposed to light, heat, and changes in pH.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!