A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of condom lubricants for forensic casework. | LitMetric

Analysis of condom lubricants for forensic casework.

J Forensic Sci

The Department of Chemistry, The University of Auckland, Private Bag 92019, Auckland, New Zealand.

Published: May 2007

The detection of DNA is inhibited in cases of sexual assault involving condom use. Trace evidence, including condom lubricant residues, provides crucial associative evidence in such cases. The existing Fourier transform infrared spectroscopy (FTIR) methods for lubricant analysis and detection are limited with regard to sensitivity and discrimination. The aim of this research was to establish a new method as an alternative to FTIR for the analysis of condom lubricant residues. Pyrolysis gas chromatography-mass spectrometry (PyGC-MS) and GC-MS are highly sensitive methods of analysis for a wide range of chemical substances. PyGC-MS and GC-MS were used to analyze condom lubricants in standard solution, from clean swabs and from postcoital swabs. Pyrolysis of polydimethylsiloxane (PDMS) lubricant forms cyclic products known as cyclic dimethyl siloxanes (DMS), which are separated and detected by the GC-MS. The polyethylene glycol (PEG) lubricant can be analyzed by GC-MS directly from solution. The methods of extraction and analysis presented in this paper were shown to be significantly more sensitive than FTIR for the analysis of PDMS and PEG condom lubricants. PDMS was detected as low as 1 mug in standard solution and from clean swabs using the PyGC-MS method. PEG was detected as low as 0.5 microg from standard solution and 50 mug from clean swabs using the GC-MS method. Unfortunately, we were unable to provide further discrimination between condom brands and subbrands. The methods established throughout the research were used successfully to detect condom lubricants from donated postcoital swabs. Lubricants were detected in abundance on swabs 12 h postcoitus. Recommendations are made regarding implementation of new methods for routine analysis of casework samples along with strict pyrolysis interpretation criteria to minimize the possibility of misinterpretation of false positives.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1556-4029.2007.00411.xDOI Listing

Publication Analysis

Top Keywords

condom lubricants
16
standard solution
12
solution clean
12
clean swabs
12
analysis condom
8
condom lubricant
8
lubricant residues
8
ftir analysis
8
pygc-ms gc-ms
8
postcoital swabs
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!