A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Postoperative radiotherapy for synovial sarcoma of the head and neck during pregnancy: clinical and technical management and fetal dose estimates. | LitMetric

Aims And Background: In vivo and phantom dosimetry is reported to estimate the fetal dose and evaluate the effectiveness of a special shielding device to reduce fetal exposure in a woman undergoing postoperative radiation therapy for synovial oral cavity sarcoma at the 30th week of pregnancy.

Methods: In vivo measurements were performed by placing thermoluminescent dosimeters on 3 points for fetal dose estimation: uterine fundus, umbilicus and pubis. A Rando anthropomorphic phantom was used to simulate radiotherapy. We also performed off-axis dose measurements for wedged beams to estimate the dose contribution of this accessory used in the treatment.

Results: The special shielding device reduced the fetal dose by 70% on average, despite the presence of wedges, which increased the dose by a factor of about 2.5. Before delivery the patient received 48 Gy, and from the in vivo measurements a fetal dose of 8.5, 1.7 and 0.7 cGy was estimated to the uterine fundus, umbilicus and pubis, respectively.

Conclusions: Pre-treatment simulation in the same irradiation conditions is the only reliable approach to predict the fetal dose. By using a special shielding device, radiotherapy can be optimized while keeping the fetal exposure below the risk of deterministic damage.

Download full-text PDF

Source
http://dx.doi.org/10.1177/030089160709300109DOI Listing

Publication Analysis

Top Keywords

fetal dose
24
special shielding
12
shielding device
12
dose
9
fetal
8
fetal exposure
8
vivo measurements
8
uterine fundus
8
fundus umbilicus
8
umbilicus pubis
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!