A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

CTA in the detection and quantification of vertebral artery pathologies: a correlation with color Doppler sonography. | LitMetric

CTA in the detection and quantification of vertebral artery pathologies: a correlation with color Doppler sonography.

Neuroradiology

Department of Cardiovascular and Interventional Radiology, Medical University Vienna, Währinger Gürtel 18-20, 1090 Vienna, Austria.

Published: August 2007

Introduction: We evaluated the feasibility of multidetector CT angiography (MDCTA) in the examination of vertebral artery (VA) pathologies and correlated the results with those of color Doppler sonography (CDS).

Methods: In this retrospective cohort analysis, we identified 65 patients with suspected cerebrovascular disease, who underwent MDCTA and CDS of the supraaortic vessels within a maximum period of 1 month. We evaluated the feasibility and image quality of MDCTA in this indication, compared the value of reformatted images and axial source images in the grading of stenoses and correlated these results with those of CDS.

Results: The image quality of the MDCTA examination was classified as good in 64 patients (98.5%) and as moderate in 1 patient (1.5%). Axial source images and reformatted images agreed perfectly in terms of stenosis detection and grading as well as the detection of hypoplastic VAs (kappa = 1). The correlation between MDCTA and CDS was moderate (kappa = 0.56) in terms of stenosis detection and quantification and poor (kappa = 0.35) in terms of detection of hypoplasia of the VA.

Conclusion: MDCTA is a feasible method for the evaluation of VA pathologies providing a good image quality. Image reformatting does not add any diagnostic value to the interpretation of axial source images. The correlation between MDCTA and CDS is only moderate, reflecting the clinically important limitations of CDS in this indication.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00234-007-0234-0DOI Listing

Publication Analysis

Top Keywords

mdcta cds
12
image quality
12
axial source
12
source images
12
detection quantification
8
vertebral artery
8
artery pathologies
8
color doppler
8
doppler sonography
8
evaluated feasibility
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!