The Berlin Heart INCOR system (Berlin Heart AG, Berlin, Germany) is a left ventricular assist device that generates a laminar blood flow. One of our INCOR-implanted patients was admitted to the hospital with clinical data indicating device thrombosis. The flow through the pump was assessed by contrast injection into the inflow canula. Lack of flow through the pump was found. A decision was made to perform fibrinolysis, which was performed by a reteplase injection into the device's inflow canula. After the manipulation, a restoration of the flow through the pump was observed. The patient was discharged 9 days after the procedure with no complications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.healun.2007.01.030DOI Listing

Publication Analysis

Top Keywords

flow pump
12
left ventricular
8
ventricular assist
8
assist device
8
device thrombosis
8
berlin heart
8
inflow canula
8
successful fibrinolysis
4
fibrinolysis acute
4
acute left
4

Similar Publications

Intravenous Pump Flow Accuracy: A Systematic Review.

J Infus Nurs

January 2025

Author Affiliations: Elaine Marieb College of Nursing, Elaine Marieb Center for Nursing & Engineering Innovation, University of Massachusetts Amherst, Amherst, Massachusetts.

Intravenous pumps (IVPs) deliver IV medications to millions of acute care patients each year and result in many adverse events reported to the US Food and Drug Administration (FDA). Although the use of IVPs has improved overall safety, there are still high rates of error that risk the safety of all patients, especially those of advanced age and those suffering from critical illness. Most of the documented errors are based on clinician reports, although there is reason to believe that errors due to flow rate inaccuracy go undetected and unreported.

View Article and Find Full Text PDF
Article Synopsis
  • The study showcases improvements in electrohydrodynamic (EHD) pumps alongside a new 3D-printable organohydrogel designed for soft robotics.
  • Using advanced digital light processing (DLP) technology, the researchers created a manifold pump array that can generate 90.2 kPa of pressure and deliver a flow rate of 800 mL per minute, far exceeding the capabilities of traditional EHD systems.
  • The novel organohydrogel developed has a low swelling ratio, high stretchability, and durability under stress, making it ideal for dynamic applications in soft robotics, bioengineering, and vertical farming.
View Article and Find Full Text PDF

Cardiogenic shock (CS) in acute myocardial infarction (AMI) is a life-threatening syndrome characterized by systemic hypoperfusion that can quickly progress to multiorgan failure and death. Various devices and configurations of mechanical circulatory support (MCS) exist to support patients, each with unique pathophysiological characteristics. The Intra-aortic balloon pump can improve coronary perfusion, decrease afterload, and indirectly augment cardiac output.

View Article and Find Full Text PDF

Impact of Complications on Survival Outcomes in Different Temporary Mechanical Circulatory Support Techniques: A Large Retrospective Cohort Study of Cardiac Surgical and Non-surgical Patients.

J Heart Lung Transplant

December 2024

DZHK (German Centre for Cardiovascular Research), Partner Site Berlin, 13353 Berlin, Germany; Deutsches Herzzentrum der Charité, Department of Cardiothoracic and Vascular Surgery, Berlin, Germany. Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany.

Background: Temporary mechanical circulatory support (tMCS) devices have become a standard treatment option in cardiogenic shock but are associated with high complication rates. This study analyzes common complications associated with modern tMCS devices and their impact on mortality depending on the tMCS approach.

Methods: We conducted a retrospective single-center analysis of patients with all-cause cardiogenic shock treated with veno-arterial extracorporeal life support, microaxial flow pump, and a combination of both (ECMELLA).

View Article and Find Full Text PDF

Veno-Arterial Extracorporeal Membrane Oxygenation (VA-ECMO) Support in New Era of Heart Transplant.

Transpl Int

January 2025

Cardiac Surgery Unit, Department of Precision and Regenerative Medicine and Ionian Area (DiMePRe-J), University of Bari Aldo Moro, Bari, Italy.

Heart failure is a serious and challenging medical condition characterized by the inability of the heart to pump blood effectively, leading to reduced blood flow to organs and tissues. Several underlying causes may be linked to this, including coronary artery disease, hypertension, or previous heart attacks. Therefore, it is a chronic condition that requires ongoing management and medical attention.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!