We tested the in vitro activity of 4 antimicrobial agents against methicillin-resistant Staphylococcus aureus and coagulase-negative staphylococci recovered from patients with endocarditis or bone and joint infection. Ceftobiprole, daptomycin, linezolid, and vancomycin MIC(90) values were 1, 1, 2, and 1 microg/mL, respectively. Ceftobiprole, daptomycin, linezolid, and vancomycin MBC(90) values were 2, 4, > or = 128, and 8 microg/mL, respectively. Ceftobiprole MIC and MBC values were < or = 2 microg/mL for all isolates tested, with the exception of one methicillin-resistant coagulase-negative Staphylococcus spp isolate. Vancomycin lacked bactericidal activity (defined as an MBC/MIC ratio of > or = 32) against 2 methicillin-resistant Staphylococcus aureus (MRSA) isolates from patients with bone and joint infection; one of these isolates was additionally daptomycin nonsusceptible (daptomycin MIC, 2 microg/mL). There was one additional daptomycin nonsusceptible (daptomycin MIC, 2 microg/mL) isolate (MRSA associated with bone and joint infection). Ceftobiprole demonstrated in vitro bactericidal activity against all MRSA and methicillin-resistant coagulase-negative staphylococci tested.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.diagmicrobio.2007.02.010DOI Listing

Publication Analysis

Top Keywords

bone joint
16
joint infection
16
ceftobiprole daptomycin
12
daptomycin linezolid
12
linezolid vancomycin
12
vitro activity
8
endocarditis bone
8
methicillin-resistant staphylococcus
8
staphylococcus aureus
8
coagulase-negative staphylococci
8

Similar Publications

The purpose of this study was to evaluate the radiographic outcomes of distal chevron metatarsal osteotomy associated with lateral joint capsule split as only lateral soft tissue release in patients with symptomatic moderate and severe hallux valgus (HV) deformity. Ninety patients (103 feet) at our institution between January 2014 and December 2019 were included in the present retrospective study. Each patient was evaluated preoperatively and at final follow-up by means of weight bearing radiographs lateral and dorsoplantar views.

View Article and Find Full Text PDF

High tibial osteotomy (HTO) is a widely used procedure for delaying knee arthroplasty, correcting alignment, and relieving symptoms in patients with knee osteoarthritis. Recently, proximal fibular osteotomy (PFO) has emerged as a less invasive and more cost-effective alternative. This study compares the outcomes of HTO and PFO to evaluate whether PFO can deliver results comparable to HTO in similar patient populations.

View Article and Find Full Text PDF

: The main aim of this paper was to perform the morphological assessment of children's mandibles of different etiology of dys-functions within the temporomandibular joint, from isolated idiopathic ankylosis to craniofacial malformations co-existing with genetic disorders. : The investigations encompassed seven patients at the age of 0-3. Measurements were conducted on the basis of data obtained from computed tomography.

View Article and Find Full Text PDF

: The purpose of this study was to investigate dynamic responses of Lenke1B+ spines of adolescent scoliosis patients to different frequencies. : Modal analysis, harmonic response analysis and transient dynamics of a full spine model inverted by the finite element method using Abaqus. : The first-order axial resonance frequency of 4.

View Article and Find Full Text PDF

Evaluation of frictional wear in a follow-up screw-rod kinematic node in GGS transpedicular stabilization.

Acta Bioeng Biomech

September 2024

Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Wrocław, Poland.

: The aim of this study was to evaluate the abrasive wear of the sliding screw-rod joint used in growth guidance system (GGS) stabilizers, allowing for the translation of the screw along the rod during the spinal growth process in a standard and modified system. : The study used single kinematic screw-rod pairs made of titanium alloy Ti6Al4V. Mechanical tests (cyclic loads) simulated the stabilizer's operation under conditions similar to actual use.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!