Acousto-optic tunable filter imaging spectrometer with full Stokes polarimetric capability.

Appl Opt

U.S. Army Research Laboratory, Maryland 20783-1197, USA.

Published: May 2007

Polarization is an important addition to spectral imaging in detecting and identifying objects of interest, and simple linear polarization measurements are often inadequate. Full polarization analysis can give additional information for discrimination where the polarization state is completely described by the Stokes parameters. An acousto-optic tunable filter (AOTF) imaging system was built incorporating two liquid-crystal variable retarders (LCVRs) that can provide complete spectral-polarimetric analysis, and it is believed to be the first demonstration of a full Stokes polarimetric AOTF spectral imaging system with no moving parts. It is also shown that a single LCVR cannot provide all the Stokes parameters.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.46.002632DOI Listing

Publication Analysis

Top Keywords

acousto-optic tunable
8
tunable filter
8
full stokes
8
stokes polarimetric
8
spectral imaging
8
stokes parameters
8
imaging system
8
imaging
4
filter imaging
4
imaging spectrometer
4

Similar Publications

The acousto-optic modulation over a broad near-infrared (NIR) spectrum with high speed, excellent integrability, and relatively simple scheme is crucial for the application of next-generation opto-electronic and photonic devices. This study aims to experimentally demonstrate ultrafast acousto-optic phenomena in the broad NIR spectral range of 0.77-1.

View Article and Find Full Text PDF

Design of Acoustic Absorbing Structures for Mercurous Halide-Based Acousto-Optic Tunable Filters.

Materials (Basel)

November 2024

School of Instrumentation and Opto-Electronic Engineering, Beihang University, Beijing 100191, China.

For the acousto-optic tunable filter (AOTF)-based spectral imaging systems, the diffraction efficiency of the AOTF is a primary factor affecting system throughput. Moreover, the distribution of the acoustic field within the AOTF fundamentally determines the device's diffraction efficiency. Thus, the design of an AOTF device including a transducer and absorber to achieve a uniform acoustic field distribution plays an important role in improving diffraction efficiency.

View Article and Find Full Text PDF

Spatial-Dependent Spectral Response of Acousto-Optic Tunable Filters with Inhomogeneous Acoustic Distribution.

Materials (Basel)

September 2024

School of Instrumentation and Opto-Electronic Engineering, Beihang University, Beijing 100191, China.

The spectral response of an acousto-optic tunable filter (AOTF) is crucial for an AOTF based spectral imaging system. The acousto-optic (AO) interaction within the spatial-distributed area of the acoustic field determines the spectral response of the light incidence. Assuming an ideally uniform acoustic field distribution, phase-matching geometries can be applied to calculate the anisotropic Bragg diffraction in AO interactions, determining the wavelength and direction of the diffracted light.

View Article and Find Full Text PDF

Quasi-collinear geometry is a special configuration of acousto-optic (AO) diffraction that applies the acoustic wave reflection from the AO cell input optical face and provides an extremely large interaction length for achieving abnormally high spectral resolution of AO tunable filters. As a result, it becomes possible to implement the multifrequency diffraction which has found important applications for laser pulse shaping. The operation of quasi-collinear AO devices in the multifrequency diffraction regimen is accompanied by the appearance of the longitudinal and transverse temperature gradients in the crystal, mainly due to the acoustic power absorption.

View Article and Find Full Text PDF

Significance: Histopathological examination of surgical biopsies, such as in glioma and glioblastoma resection, is hindered in current clinical practice by the long time required for the laboratory analysis and pathological screening, typically taking several days or even weeks to be completed.

Aim: We propose here a transportable, high-density, spectral scanning-based hyperspectral imaging (HSI) setup, named HyperProbe1, that can provide , fast biochemical analysis, and mapping of fresh surgical tissue samples, right after excision, and without the need for fixing, staining nor compromising the integrity of the tissue properties.

Approach: HyperProbe1 is based on spectral scanning via supercontinuum laser illumination filtered with acousto-optic tunable filters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!