A simple and sensitive liquid chromatography with amperometric detection was developed for the first time to monitor the protein-unbound acteoside in the rat blood and brain microdialysate by microdialysis technique. Microdialysis samples without further cleanup procedures were directly injected into the HPLC and separated using a reversed-phase C18 column (150 mmx2 mm, i.d. 5 microm) maintained at ambient temperature and a mobile phase comprised of acetonitrile-50 mM monosodium phosphate (pH 2.8) (17:83, v/v) with a flow rate of 0.2 mL/min. Based on the experimental voltamogram, the applied potential was set at +0.9 V oxidative mode. The concentration-response relationship was linear (r2>0.99) over a concentration range of 5-500 ng/mL; method precision and accuracy fell within predefined limits (less than 20%). The developed method was applied to assess the pharmacokinetics of acteoside, and the results suggested that acteoside was fitted better by the two-compartmental model following a single intravenous injection of acteoside. Acteoside was unable to be detected in the brain dialysate. The distribution and elimination half-lives of unbound acteoside in the blood were 5 and 28 min, respectively, which suggested the rapid distribution of acteoside.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2007.03.033DOI Listing

Publication Analysis

Top Keywords

amperometric detection
8
acteoside
8
acteoside rat
8
rat blood
8
blood brain
8
liquid chromatographic
4
chromatographic method
4
method amperometric
4
detection determine
4
determine acteoside
4

Similar Publications

Aminated carbon nanotubes, CNT, were covalently modified with glutardialdehyde (GDI) and the redox dye Azure to form a new electrode material CNT-GDI-Azure (CGA). The nanocomposite of CGA and polysaccharide chitosan was used for the anodic determination of NADH. Compared to conventional carbon and metal electrodes, the CGA electrode drastically lowered the overpotential for NADH oxidation (by > 0.

View Article and Find Full Text PDF

Portable Amperometric Biosensor Enhanced with Enzyme-Ternary Nanocomposites for Prostate Cancer Biomarker Detection.

Biosensors (Basel)

December 2024

Department of Cogno-Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan 46241, Republic of Korea.

Enzyme-based portable amperometric biosensors are precise and low-cost medical devices used for rapid cancer biomarker screening. Sarcosine (Sar) is an ideal biomarker for prostate cancer (PCa). Because human serum and urine contain complex interfering substances that can directly oxidize at the electrode surface, rapid Sar screening biosensors are relatively challenging and have rarely been reported.

View Article and Find Full Text PDF

Synergistic effect of Zr MOF modified functionalized carbon nano fibres for determination of tert-butylhydroquinone in food samples.

Food Chem

December 2024

International Ph.D. Program in Innovative Technology of Biomedical Engineering and Medical Devices, Ming Chi University of Technology, New Taipei City 243303, Taiwan; Research Center for Intelligence Medical Devices, Ming Chi University of Technology, New Taipei City 243303, Taiwan; Centre for Applied Research, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences (SIMATS), Chennai 602105, Tamil Nadu, India. Electronic address:

In modern life, people often neglect to consider their eating habits. Antioxidants are primarily used as food additives due to their stability and low toxicity. TBHQ is a commonly used antioxidant in food products as an additive.

View Article and Find Full Text PDF

Advancements in glycan analysis: high performance anion exchange chromatography-pulsed amprometric detection coupled with mass spectrometry for structural elucidation.

J Pharm Biomed Anal

December 2024

College of Pharmaceutical Sciences and Key Laboratory of Translational Research and Therapy for Neuro-Psycho-Diseases, Soochow University, Suzhou, Jiangsu 215021, China. Electronic address:

Carbohydrates are essential biomolecules that play a vital role in various biological processes across humans, plants, and bacteria. Despite their ubiquity, the structural elucidation of carbohydrates, particularly oligo- and polysaccharides, remains a significant challenge due to their complex and heterogeneous nature. The high-performance anion exchange chromatography (HPAEC) or called ion chromatography (IC) coupled with pulsed amperometric detection (PAD) has emerged as a powerful tool for highly effective separation and highly specific detection of glycans.

View Article and Find Full Text PDF

Various commercial and industrial products widely use highly toxic eight-carbon-chain perfluorooctanesulfonate (PFOS), posing a significant threat to the health of living organisms. In this study, the electrochemical detection of PFOS was achieved by developing a carbon paste electrode (CPE) using the MoTiAlC MAX phase. MoTiAlC was synthesized and directly used to construct the CPE.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!