Structural mapping of proteins and nucleic acids with high resolution in solution is of critical importance for understanding their biological function. A wide range of footprinting technologies have been developed over the last ten years to address this need. Beamline X28C, a white-beam X-ray source at the National Synchrotron Light Source of Brookhaven National Laboratory, functions as a platform for synchrotron footprinting research and further technology development in this growing field. An expanding set of user groups utilize this national resource funded by the National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health. The facility is operated by the Center for Synchrotron Biosciences and the Center for Proteomics of Case Western Reserve University. The facility includes instrumentation suitable for conducting both steady-state and millisecond time-resolved footprinting experiments based on the production of hydroxyl radicals by X-rays. Footprinting studies of nucleic acids are routinely conducted with X-ray exposures of tens of milliseconds, which include studies of nucleic acid folding and their interactions with proteins. This technology can also be used to study protein structure and dynamics in solution as well as protein-protein interactions in large macromolecular complexes. This article provides an overview of the X28C beamline technology and defines protocols for its adoption at other synchrotron facilities. Lastly, several examples of published results provide illustrations of the kinds of experiments likely to be successful using these approaches.

Download full-text PDF

Source
http://dx.doi.org/10.1107/S0909049507013118DOI Listing

Publication Analysis

Top Keywords

beamline x28c
8
center synchrotron
8
synchrotron biosciences
8
national resource
8
structure dynamics
8
synchrotron footprinting
8
nucleic acids
8
studies nucleic
8
synchrotron
6
national
6

Similar Publications

Fabrication and testing of a prototype transmission-mode pixelated diamond X-ray detector (pitch size 60-100 µm), designed to simultaneously measure the flux, position and morphology of an X-ray beam in real time, are described. The pixel density is achieved by lithographically patterning vertical stripes on the front and horizontal stripes on the back of an electronic-grade chemical vapor deposition single-crystal diamond. The bias is rotated through the back horizontal stripes and the current is read out on the front vertical stripes at a rate of ∼ 1 kHz, which leads to an image sampling rate of ∼ 30 Hz.

View Article and Find Full Text PDF

Synchrotron X-ray footprinting on tour.

J Synchrotron Radiat

January 2014

Center for Synchrotron Biosciences, Case Western Reserve University, National Synchrotron Light Source, Brookhaven National Laboratory, Upton, NY 11973, USA.

Synchrotron footprinting is a valuable technique in structural biology for understanding macromolecular solution-state structure and dynamics of proteins and nucleic acids. Although an extremely powerful tool, there is currently only a single facility in the USA, the X28C beamline at the National Synchrotron Light Source (NSLS), dedicated to providing infrastructure, technology development and support for these studies. The high flux density of the focused white beam and variety of specialized exposure environments available at X28C enables footprinting of highly complex biological systems; however, it is likely that a significant fraction of interesting experiments could be performed at unspecialized facilities.

View Article and Find Full Text PDF

Development of diamond-based X-ray detection for high-flux beamline diagnostics.

J Synchrotron Radiat

November 2010

Center for Synchrotron Biosciences, Case Western Reserve University, Upton, NY 11973, USA.

High-quality single-crystal and polycrystalline chemical-vapor-deposition diamond detectors with platinum contacts have been tested at the white-beam X28C beamline at the National Synchrotron Light Source under high-flux conditions. The voltage dependence of these devices has been measured under both DC and pulsed-bias conditions, establishing the presence or absence of photoconductive gain in each device. Linear response consistent with the theoretically determined ionization energy has been achieved over eleven orders of magnitude when combined with previous low-flux studies.

View Article and Find Full Text PDF

Installation and testing of a focusing mirror at beamline X28C for high flux x-ray radiolysis of biological macromolecules.

Rev Sci Instrum

February 2008

Center for Proteomics and Mass Spectrometry and Center for Synchrotron Biosciences, Case Western Reserve University, Cleveland, Ohio 44106-4988, USA.

The NSLS X28C white-light beamline has been upgraded with a focusing mirror in order to provide increased x-ray density and a wide selection of beam shapes at the sample position. The cylindrical single crystal silicon mirror uses an Indalloy 51 liquid support bath as both a mechanism for heat transfer and a buoyant support to counter the effects of gravity and correct for minor parabolic slope errors. Calorimetric measurements were performed to verify that the calculated more than 200-fold increase in flux density is delivered by the mirror at the smallest beam spot.

View Article and Find Full Text PDF

Structural mapping of proteins and nucleic acids with high resolution in solution is of critical importance for understanding their biological function. A wide range of footprinting technologies have been developed over the last ten years to address this need. Beamline X28C, a white-beam X-ray source at the National Synchrotron Light Source of Brookhaven National Laboratory, functions as a platform for synchrotron footprinting research and further technology development in this growing field.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!