Convection-enhanced delivery (CED) is a novel drug delivery technique that uses positive infusion pressure to deliver therapeutic agents directly into the interstitial spaces of the brain. Despite the promise of CED, clinical trials have demonstrated that target-tissue anatomy and patient-specific physiology play a major role in drug distribution using this technique. In this study, we retrospectively tested the ability of a software algorithm using MR diffusion tensor imaging to predict patient-specific drug distributions by CED. A tumor-targeted cytotoxin, cintredekin besudotox (interleukin 13-PE38QQR), was coinfused with iodine 123-labeled human serum albumin (123I-HSA), in patients with recurrent malignant gliomas. The spatial distribution of 123I-HSA was then compared to a drug distribution simulation provided by the software algorithm. The algorithm had a high sensitivity (71.4%) and specificity (100%) for identifying the high proportion (7 of 14) of catheter trajectories that failed to deliver drug into the desired anatomical region (p = 0.021). This usually occurred when catheter trajectories crossed deep sulci, resulting in leak of the infusate into the subarachnoid cerebrospinal fluid space. The mean concordance of the volume of distribution at the 50% isodose level between the actual 123I-HSA distribution and simulation was 65.75% (95% confidence interval [CI], 52.0%-79.5%), and the mean maximal inplane deviation was less than 8.5 mm (95% CI, 4.0-13.0 mm). The use of this simulation algorithm was considered clinically useful in 84.6% of catheters. Routine use of this algorithm, and its further developments, should improve prospective selection of catheter trajectories, and thereby improve the efficacy of drugs delivered by this promising technique.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1907410 | PMC |
http://dx.doi.org/10.1215/15228517-2007-007 | DOI Listing |
Pediatr Cardiol
December 2024
Division of Cardiology, Department of Pediatrics, Stanford University School of Medicine, Lucile Packard Children's Hospital, Palo Alto, CA, USA.
Absence of the ductus arteriosus (DA) is common in tetralogy of Fallot (TOF), occurring in up to 30% of cases. Yet, the clinical course and fetal echocardiographic features are not well described, limiting prenatal counseling. This study examines the fetal echocardiographic characteristics and perinatal outcomes in children with TOF absent DA (TOF/ADA), comparing them to those with a DA (TOF/DA).
View Article and Find Full Text PDFWorld J Methodol
December 2024
Division of Nephrology, Medical College of Wisconsin, Milwaukee, WI 53226, United States.
Point-of-care ultrasound (POCUS) is a limited ultrasound examination performed by the clinician at the bedside, emerging as a complement to physical examination across various medical specialties. In the field of nephrology, its integration has been gradual, primarily limited to guiding procedures like temporary dialysis catheter placement or, in some cases, diagnostic kidney ultrasounds. In reality, the assessment of hemodynamic status at the bedside holds immense value for nephrologists, yet there exists limited awareness among practitioners regarding its implementation.
View Article and Find Full Text PDFActa Biomater
January 2025
Department of Biomedical Engineering, School of Pharmaceutical University, Shenyang 110016, China. Electronic address:
Patient Saf Surg
December 2024
Division of Neurosurgery, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA.
Background: External ventricular drain (EVD) insertion is one of the most commonly performed neurosurgical procedures. Herein, we introduce a new concept of a cranial fixation device for insertion of EVDs, that reduces reliance on freehand placement and drilling techniques and provides a simple, minimally invasive approach that provides strong fixation to minimal thickness skulls.
Methods: An experimental device for catheter insertion and fixation was designed and tested in both ex-vivo and in-vivo conditions to assess accurate cannulation of the ventricle and to test the strength of fixation to the skull.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!