Whereas femoral component modularity allows the surgeon to address a variety of femoral defects in complex total hip arthroplasty (THA), breakage of modular stems is a known complication that typically occurs at the taper junction. In response, a proprietary process of taper roller-hardening that increases taper strength by a factor of 3.5 was introduced in 1999. The authors reviewed a consecutive series of patients by a single surgeon who underwent cementless revision or difficult primary THA with a taper roller-hardened modular calcar replacement prosthesis, and have the potential for a minimum of two-year follow up. In 116 patients, 123 hips were involved. Two surgeries were primary, 101 were revision/conversion, 18 were for reimplantation after treatment of infection, and two were intramedullary total femur constructs, one of which was a reimplantation after sepsis. The patients' ages at surgery averaged 71 years, and BMIs averaged 28.12 kg/m2. Nine of the patients, all with single hip involvement, were lost to contact. Twenty-one patients, three of whom had bilateral hip involvement, expired during the follow-up period with implant outcome known. Follow up in the patients who survived averaged 44 (range: 18-78) months. Six femoral components have been revised: two (1.6%) due to recurrent sepsis, three (2.4%) due to sepsis, one (0.8%) from periprosthetic fracture, and none from septic loosening or component breakage. Survivorship with aseptic loosening as the end-point was 100%. In this series, roller-hardening appears to improve the durability of the tapered junction. No roller-hardened modular calcar devices have failed due to component breakage. However, their use is not recommended in the totally deficient proximal femur, as fatigue breaks of distally fixed monoblock extensively coated stems have been reported. Caution is advised when potting or anchoring any stem in the femoral diaphysis without reconstituting proximal bone stock and support.

Download full-text PDF

Source

Publication Analysis

Top Keywords

modular calcar
12
calcar replacement
8
replacement prosthesis
8
taper junction
8
total hip
8
hip arthroplasty
8
patients single
8
roller-hardened modular
8
hip involvement
8
component breakage
8

Similar Publications

Background: The incidence of hip fractures is increasing every year worldwide. Even though hemiarthroplasty is one of the most common procedures performed for a fractured neck of the femur, there is very little research comparing the outcomes of monoblock and modular systems, the two most commonly used prostheses in neck of the femur fractures. It was hypothesized that in narrow femoral canals, the single-size monoblock stem would be more difficult to insert and lead to complications like limb lengthening and intra-operative calcar fractures.

View Article and Find Full Text PDF

Midterm Comparative Analysis of Short Femoral Stem Survivorship in Dorr Type A Femurs.

Clin Orthop Surg

April 2024

Department of Orthopedic Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Korea.

Background: Proximal-distal mismatch has emerged as a prominent concern in Dorr type A femoral morphology, prompting the exploration of short stems as promising alternatives to conventional stems. This study aimed to evaluate clinical and radiographic outcomes of total hip arthroplasty (THA) using short femoral stems in Dorr type A proximal femoral morphology with a minimum follow-up of 5 years.

Methods: Patients with short femoral stems in Dorr type A between 2011 and 2017 were included.

View Article and Find Full Text PDF

Background: Several management strategies have been described to treat intraoperative calcar fractures during total hip arthroplasty (THA), including retaining the primary implant and utilizing cerclage cables (CCs) or switching the implant to one that bypasses the fracture and achieves diaphyseal fixation. However, the radiographic and clinical outcomes of these differing strategies have never been described and compared.

Methods: We retrospectively identified 50 patients who sustained an intraoperative calcar fracture out of 9,129 primary total hip arthroplasties (0.

View Article and Find Full Text PDF

Background: Since the introduction of stemless anatomic shoulder arthroplasty, many studies have been published on anatomic implants. For reverse stemless implants, however, there are only a few clinical follow-up studies available. The current clinical case series aims to present clinical and radiological outcomes of a new stemless reverse prosthesis system (Lima Shoulder Modular Replacement stemless).

View Article and Find Full Text PDF

Aims: Hip arthroplasty does not always restore normal anatomy. This is due to inaccurate surgery or lack of stem sizes. We evaluated the aptitude of four total hip arthroplasty systems to restore an anatomical and medialized hip rotation centre.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!