In making noninvasive measurements of the human cone mosaic, the task of labeling each individual cone is unavoidable. Manual labeling is a time-consuming process, setting the motivation for the development of an automated method. An automated algorithm for labeling cones in adaptive optics (AO) retinal images is implemented and tested on real data. The optical fiber properties of cones aided the design of the algorithm. Out of 2153 manually labeled cones from six different images, the automated method correctly identified 94.1% of them. The agreement between the automated and the manual labeling methods varied from 92.7% to 96.2% across the six images. Results between the two methods disagreed for 1.2% to 9.1% of the cones. Voronoi analysis of large montages of AO retinal images confirmed the general hexagonal-packing structure of retinal cones as well as the general cone density variability across portions of the retina. The consistency of our measurements demonstrates the reliability and practicality of having an automated solution to this problem.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/josaa.24.001358 | DOI Listing |
BMC Ophthalmol
January 2025
Department of Retina and Vitreous, Narayana Nethralaya, #121/C, 1st R Block, Chord Road, Rajaji Nagar, Bengaluru, Karnataka, 560010, India.
Background: Accurate localization of premacular hemorrhages (PMHs) is crucial as treatment strategies vary significantly based on whether the hemorrhage resides within the vitreous gel, subhyaloid space, or beneath the internal limiting membrane (ILM). This report outlines the clinical features, diagnostic findings, and treatment outcomes in a patient diagnosed with a PMH secondary to suspected Valsalva retinopathy.
Methods: This is a retrospective interventional case report.
Br J Ophthalmol
January 2025
Department of Neurosciences, Imaging and Clinical Sciences, University "G. d'Annunzio" Chieti-Pescara, Chieti, Italy.
Purpose: To quantitatively explore preretinal abnormal tissue (PAT) in macula-on rhegmatogenous retinal detachment (RRD) before and after surgery.
Methods: In this case-series study, PAT was detected by en-face optical coherence tomography images with custom slabs in eyes that underwent pars plana vitrectomy and SF6 for macula-on RRD.Main outcome measures were PAT area at baseline, 3-month and 6-month follow-up, and its relative change.
Retin Cases Brief Rep
December 2024
Department of Ophthalmology, Hospital de Clínicas, University of Buenos Aires, Buenos Aires, Argentina.
Purpose: to report optical coherence tomography angiography findings in syphilitic outer retinopathy, a singular clinical manifestation of ocular syphilis.
Methods: case report.
Results: Multimodal imaging including optical coherence tomography angiography was performed in a patient presenting syphilitic outer retinopathy.
Retin Cases Brief Rep
December 2024
Department of Ophthalmology and Visual Neurosciences, University of Minnesota, Minneapolis, MN, USA.
Purpose: To report the clinical presentation, treatment course, and outcome of a case of bilateral frosted branch angiitis (FBA) and neuroretinitis associated with acute Epstein-Barr virus (EBV) infection in a pediatric patient with Turner Syndrome.
Methods: Case report with multimodal ocular imaging and extensive systemic workup.
Results: A 16-year-old female with Turner syndrome presented with acute bilateral vision loss, hearing loss, and ataxia.
Sci Adv
January 2025
Department of Micro/Nano Electronics, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
Retinomorphic systems that can see, recognize, and respond to real-time environmental information will extend the complexity and range of tasks that an exoskeleton robot can perform to better assist physically disabled people. However, the lack of ultrasensitive, reconfigurable, and large-scale integratable retinomorphic devices and advanced edge-processing algorithms makes it difficult to realize retinomorphic hardware. Here, we report the retinomorphic hardware prototype with a 4096-pixel perovskite image sensor array as core module to endow embodied intelligent vision functionalities.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!