Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices.

J Opt Soc Am A Opt Image Sci Vis

Schepens Eye Research Institute and Department of Ophthalmology, Harvard Medical School, and Wellman Center for Photomedicine, Massachusetts General Hospital, Boston 02114, USA.

Published: May 2007

After discussing the rationale and assumptions of the ANSI Z136.1-2000 Standard for protection of the human eye from laser exposure, we present the concise formulation of the exposure limits expressed as maximum permissible radiant exposure (in J/cm(2)) for light overfilling the pupil. We then translate the Standard to a form that is more practical for typical ophthalmic devices or in vision research situations, implementing the special qualifications of the Standard. The safety limits are then expressed as radiant power (watts) entering the pupil of the eye. Exposure by repetitive pulses is also addressed, as this is frequently employed in ophthalmic applications. Examples are given that will familiarize potential users with this format.

Download full-text PDF

Source
http://dx.doi.org/10.1364/josaa.24.001250DOI Listing

Publication Analysis

Top Keywords

maximum permissible
8
ophthalmic devices
8
limits expressed
8
permissible exposures
4
exposures ocular
4
ocular safety
4
safety ansi
4
ansi 2000
4
2000 emphasis
4
emphasis ophthalmic
4

Similar Publications

Rice yield could be increased by apply higher level of nitrogen fertilizer, but excessive use of nitrogen fertilizer will cause plant lodging. This study aimed to investigate the effect of nitrogen application rate on lodging resistance of rice stems. Four japonica rice varieties with different lodging resistance were used, and six nitrogen fertilizer levels were set up to analyze the morphological structure, mechanical properties, and chemical components of rice stems under such treatments.

View Article and Find Full Text PDF

Background: No appropriate studies have been conducted that compare the biomechanical properties of different fenestration positions in deep circumflex iliac artery (DCIA)-vascularized iliac bone grafts for femoral head necrosis (ONFH) treatment. In this study, we aimed to explore the fenestration locations of DCIA-vascularized iliac grafting in ONFH treatment using FEA and clinical retrospective analysis.

Methods: We simulated an iliac bone flap transplantation with a vascularized tip by finite element analysis (FEA).

View Article and Find Full Text PDF

Deep-UV microscopy enables high-resolution, label-free molecular imaging by leveraging biomolecular absorption properties in the UV spectrum. Recent advances in UV-imaging hardware have renewed interest in this technique for quantitative live cell imaging applications. However, UV-induced photodamage remains a concern for longitudinal dynamic imaging studies.

View Article and Find Full Text PDF

Objectives: To compare thoracolumbar fascia (TLF) shear strain between individuals with and without nonspecific low back pain (NSLBP), investigate its correlation with symptoms, and assess a standardized massage technique's impact on TLF shear strain.

Methods: Participants were prospectively enrolled between February 2021 and June 2022. Pre- and post-intervention TLF ultrasound and pain/disability questionnaires were conducted.

View Article and Find Full Text PDF

On October 11, 2018, in the Ulytau region of the Republic of Kazakhstan, the Soyuz-FG launch vehicle carrying a crewed MS-10 spacecraft failed. It resulted in the release into the fragile arid ecosystems of rocket propellants, i.e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?