Sixteen test gilts were fed an egg white-fortified practical diet and four control gilts an egg white-free diet over a two-parity period in order to monitor changes in the serum biotin levels as induced biotin deficiency progressed. Gilts were individually housed in metal crates with slatted floors. Serum biotin (ng/L) of test animals declined from 1490 (initially) to 610 (month 3), remained stable (months 4-8) and thereafter approached 400, 135 and 30 after months 9, 13 and 15, respectively. Early clinical symptoms, i.e. lesions (on the feet, legs and skin), hoof cracks, hair loss and dry skin, were first observed after six months and became progressively more pronounced with time. After nine months, the induced symptoms resembled those characteristic of biotin deficiency. In contrast, serum biotin remained high in the control animals which did not develop symptoms. The data are interpreted to mean that serum biotin might be used as a sensitive index of biotin deficiency development in sows. On the basis of these observations, a system is proposed for evaluation of the sow's biotin status. Adequate biotin may be indicated by serum biotin level (ng/L) > 700; marginal, > 600 < 700; inadequate, > 400 < 600; and deficient, < 400. Alternatively, several concurrent clinical symptoms (i.e. alopecia, hoof cracks and lesions on the feet, legs and skin) may aid in the diagnosis of inadequate biotin status of sow herds reared under field conditions.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1680218 | PMC |
Talanta
January 2025
State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing, 210023, China. Electronic address:
Cancer biomarkers have been facing some issues such as poor accuracy and low sensitivity in the early diagnosis of tumors. Utilizing biotin-labelled peptide as a mass tag (MT), this work proposes a high-throughput biosensing strategy for matrix-assisted laser desorption/ionization-time of flight mass spectrometric (MALDI-TOF-MS) immunoassay of multiple lung cancer biomarkers. Due to little required dosage, satisfied stability, high sensitivity and accuracy, this method can achieve off-site centralized signal detection after on-site sample incubation.
View Article and Find Full Text PDFDiagn Microbiol Infect Dis
January 2025
Department of Anatomy, Jajati Keshari Medical College and Hospital, Jajpur, Odisha, India.
Dengue virus (DENV) is an important arthropod-borne viral disease, with four antigenically and genetically diverse serotypes (DENV-1, DENV-2, DENV-3, and DENV-4). Timely and accurate diagnosis of dengue virus serotypes is crucial for the management of outbreaks. This study focussed on the development of a RT-PCR based lateral flow strip assay to detect DENV serotypes in a dual detection manner without using gel electrophoresis.
View Article and Find Full Text PDFBiosens Bioelectron
December 2024
Key Laboratory for Green Organic Synthesis and Application of Hunan Province, Key Laboratory of Environmentally Friendly Chemistry and Application of Ministry of Education, College of Chemistry, Xiangtan University, Xiangtan, 411105, China. Electronic address:
Sci Rep
December 2024
Institute of Agriculture and Life Science, Gyeongsang National University, Jinju, 52828, Republic of Korea.
Heat stress (HS) is an impactful condition in ruminants that negatively affects their physiological and rumen microbial composition. However, a fundamental understanding of metabolomic and metataxonomic mechanisms in goats under HS conditions is lacking. Here, we analyzed the rumen metabolomics, metataxonomics, and serum metabolomics of goats (n = 10, body weight: 41.
View Article and Find Full Text PDFACS Meas Sci Au
December 2024
Department of Chemistry, Oklahoma State University, Stillwater, Oklahoma 74078, United States.
This article presents a colorimetric visual biosensor designed for direct application in undiluted biofluids, which holds significant promise for point-of-need applications. Unlike traditional biosensors that struggle with heavily diluted sample matrices, the presented biosensor does not require any instrumentation or trained personnel, making it highly practical. The sensor features an oligonucleotide probe covalently attached to magnetically separable magnetite (FeO) particles.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!