A sensitive and specific liquid chromatographic method coupled with tandem mass spectrometric detection was set up and fully validated for the simultaneous quantification of vinflunine (VFL) and its pharmacologically active metabolite, 4-O-deacetyl vinflunine (DVFL). The two compounds, as well as vinblastine (used as internal standard), were deproteinised from blood and faeces, analysed on a cyano type column and detected on a Micromass Quattro II system in the positive ion mode after ionisation using an electrospray ion source. In blood, linearity was assessed up to 200 ng/ml for vinflunine and 100 ng/ml for 4-O-deacetyl vinflunine. The lower limit of quantification was validated at 250 pg/ml for both compounds. In other biological media, the linearity was assessed within the same range; the limit of quantification was adjusted according to the expected concentration levels of each compound. This method was first developed in order to identify the structures and to elucidate the metabolic pathway of vinflunine. Thanks to its high sensitivity and specificity, the method has enabled the quantification of vinflunine and 4-O-deacetyl vinflunine in blood at trace levels, and has contributed to the knowledge of vinflunine metabolism by monitoring up to 10 metabolites.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jchromb.2007.03.030 | DOI Listing |
Cancer Chemother Pharmacol
March 2013
Institut Claudius Regaud, 20-24 rue du Pont Saint-Pierre, 31052 Toulouse Cedex, France.
Purpose: Vinflunine ditartrate is a microtubule inhibitor belonging to the vinca alkaloid family. This phase I study was carried out to evaluate the maximal tolerated dose, the safety profile, the pharmacokinetics and the activity of oral vinflunine (VFL) given daily in patients with advanced/metastatic solid tumours and who have failed standard therapy.
Methods: Patients were treated with oral VFL administered once daily for 6 weeks followed by a two-week rest.
J Chromatogr B Analyt Technol Biomed Life Sci
June 2007
Institut de Recherche Pierre Fabre, Oncology Pharmacokinetic Department, 2 rue Christian d'Espic, 81106 Castres, France.
A sensitive and specific liquid chromatographic method coupled with tandem mass spectrometric detection was set up and fully validated for the simultaneous quantification of vinflunine (VFL) and its pharmacologically active metabolite, 4-O-deacetyl vinflunine (DVFL). The two compounds, as well as vinblastine (used as internal standard), were deproteinised from blood and faeces, analysed on a cyano type column and detected on a Micromass Quattro II system in the positive ion mode after ionisation using an electrospray ion source. In blood, linearity was assessed up to 200 ng/ml for vinflunine and 100 ng/ml for 4-O-deacetyl vinflunine.