A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sterilization and strength of 70/30 polylactide cages: e-beam versus ethylene oxide. | LitMetric

Study Design: In vitro and in vivo studies on the degradation of 70/30 poly(L,DL-lactide) (PLDLLA) cages.

Objective: To evaluate the effect of e-beam and ethylene oxide sterilization on degradation and strength.

Summary Of Background Data: e-beam-sterilized PLDLLA cages were shown to maintain mechanical strength for at least 6 months during degradation studies in vitro. Yet failure of the cages was observed after only 3 months in vivo. We hypothesized that degradation characteristics and mechanical strength could be improved by sterilizing the cages through ethylene oxide (EtO) instead of e-beam.

Methods: PLDLLA cages were sterilized either by e-beam or EtO, and degraded in phosphate-buffered saline. Each month, cages were compressed until failure. Inherent viscosity was determined as a measure of degradation. For the in vivo evaluation, e-beam- or EtO-sterilized cages were implanted at L3-L4 in a standardized goat model. After 3 or 6 months, retrieved segments were scanned by high-resolution magnetic resonance imaging. Also, inherent viscosity of the polymer was measured.

Results: e-beam sterilization strongly decreased inherent viscosity of PLDLLA compared with EtO sterilization, but initial strength was only affected marginally. After 6 months, the strength of the e-beam-sterilized cages dropped, while that of EtO-sterilized cages was maintained. Degradation in vivo was slightly faster than in vitro. In both groups, however, mechanical failure occurred at 3 months after implantation.

Conclusions: Inherent viscosity decreases with degradation time, but strength only decreases when inherent viscosity is below a certain threshold. Above this threshold, mechanical strength is a property of the polymer and independent of inherent viscosity. e-beam sterilization strongly decreases inherent viscosity and thus advances mechanical degradation. EtO sterilization delays degradation but does not increase initial strength. Early failure of PLDLLA cages in the goat model thus is unrelated to sterilization method and requires further study.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.brs.0000259057.94986.3bDOI Listing

Publication Analysis

Top Keywords

inherent viscosity
28
ethylene oxide
12
pldlla cages
12
mechanical strength
12
cages
10
degradation
9
degradation vivo
8
eto-sterilized cages
8
goat model
8
e-beam sterilization
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!