Introduction: The safety of dose-escalated thoracic radiation concurrent with gemcitabine in patients with inoperable stage III non-small cell lung cancer has not been studied.
Patients And Materials: The maximal tolerated dose of 35 mg/m twice-weekly gemcitabine and concurrent standard thoracic radiation was established in a previous phase Ia trial. In this study, a second patient cohort (phase Ib) received twice-weekly gemcitabine concurrent with three-dimensional dose-escalated thoracic radiation (60-74 Gy) after two cycles of induction chemotherapy: gemcitabine (1000 mg/m) day 1 and 8 and carboplatin (area under the curve 5.0-5.5) day 1 every 21 days.
Results: Twenty-three patients were entered in the phase Ib portion of this trial. Grade III/IV hematologic toxicity was primarily thrombocytopenia (22%) and neutropenia (26%). Grade III/IV esophageal toxicities occurred in 17% of patients, and grade III radiation pneumonitis/dyspnea was observed in 7 of 23 patients. The median and 2-year survival for phase Ib patients were 17.4 months and 32%, respectively. The overall 1- and 2-year survival for all 39 patients (16 phase Ia, 23 phase Ib) was 69% and 32%, respectively.
Conclusions: Combining 74-Gy thoracic radiation and concurrent gemcitabine is feasible, but the use of this regimen should be limited to the confines of a clinical trial. A randomized phase II trial through the Cancer and Leukemia Group B is underway to further evaluate the efficacy of this regimen.
Download full-text PDF |
Source |
---|
Med Phys
January 2025
Department of Engineering Physics, Tsinghua University, Beijing, China.
Background: X-ray grating-based dark-field imaging can sense the small angle scattering caused by object's micro-structures. This technique is sensitive to the porous microstructure of lung alveoli and has the potential to detect lung diseases at an early stage. Up to now, a human-scale dark-field CT (DF-CT) prototype has been built for lung imaging.
View Article and Find Full Text PDFAcad Radiol
January 2025
Medical Image Processing Group, 602 Goddard building, 3710 Hamilton Walk, Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104 (M.L., M.A., J.K.U., Y.T., C.W., N.P., S.M., D.A.T.). Electronic address:
Rationale And Objectives: Cardiovascular toxicity is a well-known complication of thoracic radiation therapy (RT), leading to increased morbidity and mortality, but existing techniques to predict cardiovascular toxicity have limitations. Predictive biomarkers of cardiovascular toxicity may help to maximize patient outcomes.
Methods: The machine learning optimal biomarker (OBM) method was employed to predict development of cardiotoxicity (based on serial echocardiographic measurements of left ventricular ejection fraction and longitudinal strain) from computed tomography (CT) images in patients with thoracic malignancy undergoing RT.
Curr Opin Allergy Clin Immunol
January 2025
Department of Pulmonology, Allergy and Thoracic Oncology, University Hospital of Montpellier, Montpellier, France.
Purpose Of Review: Climate change influences working conditions in various ways, affecting employee health and safety across different sectors. Climatic factors like rising temperatures, increased UV radiation, and more frequent extreme weather events pose risks to in both indoor and outdoor workers. Allergic diseases of the respiratory tract and the skin may emerge due to climate change.
View Article and Find Full Text PDFJ Thorac Oncol
January 2025
Division of Thoracic Surgery, Keio University School of Medicine, Tokyo, Japan.
Introduction: Pulmonary high-grade neuroendocrine carcinoma (NEC) includes small cell lung carcinoma (SCLC) and large cell neuroendocrine carcinoma (LCNEC). The seventh and eighth editions of the TNM classification for lung cancer confirmed the applicability of this staging system for SCLC. With the proposal of N2 and M1c subcategories for the ninth edition classification, we assessed the applicability to NECs.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Cardiovascular Surgery, Houston Methodist Hospital, 6550 Fannin St, Houston, TX 77030, USA.
: The aim of this study was to compare the outcomes of stiff wire-based 2D3D, 3D3D image fusion (IF), and non-image fusion techniques for simple zone 2 and zone 3 TEVAR cases in terms of radiation exposure, contrast dose, and fusion and projection accuracy. : A single-center retrospective observational study was conducted based on data gathered from patients who underwent TEVAR between 2016 and 2023 at our tertiary aortic referral center. Those who underwent Z2 and Z3 TEVAR during the indicated period were included.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!