Objective: To evaluate whether a new fluid-phase filtration radioassay possesses both high sensitivity and specificity compared with the currently used ELISA and Farr assays.
Methods: Sequential sera (25 samples) from 9 patients with systemic lupus erythematosus (SLE), sera from 20 patients with SLE possessing anti-dsDNA antibodies by the Crithidia assay, 75 patients with rheumatoid arthritis possessing rheumatoid factors, 50 healthy control subjects, 767 from patients with type 1 diabetes, and a commercial standard serum sample were tested for anti-dsDNA antibodies with the 3 different assays.
Results: Of serial dilutions of a standard anti-dsDNA antibody sample, only the highest positive sample (50 IU/ml) in the ELISA and the highest 2 positive samples (50 and 25 IU/ml) in the Farr assay were above the normal range. In contrast, all dilutions (to 2.5 IU/ml) of the standard anti-dsDNA antibody sample were above the normal range in the filtration radioassay. Using the values of 50 healthy control subjects in each assay to define the normal range, all 25 sequential sera from 9 patients with SLE were positive. In addition, 20/20 of the SLE individual sera, 2/75 (2.7%) of the RA sera, and 12/767 (1.6%) of the diabetes sera were positive (signal above normal range) in the filtration radioassay. The SLE sera were further examined in 2 additional assays, ELISA and Farr assay, and both assays were less sensitive and specific compared with the filtration radioassay.
Conclusion: The fluid-phase filtration radioassay demonstrated high sensitivity and specificity for the detection of anti-dsDNA antibodies in SLE, with the standard ELISA exhibiting lower specificity. We suggest that testing for anti-dsDNA antibodies can be improved using a fluid-phase filtration radioassay in comparison to commercial assays.
Download full-text PDF |
Source |
---|
Radiat Prot Dosimetry
December 2024
Department of Oral and Maxillofacial Radiology, School of Dentistry, Yasuj University of Medical Sciences, Dr. Shahid Jalil St., Yasuj, Kohgiluyeh and Boyer-Ahmad Province, Iran.
Radiation protection in dental radiography can be achieved by adjusting the image field size, exposure, and filtration parameters, and using protective lead shields. The aim of this study is to assess the radiation dose delivered to the thyroid in a phantom irradiated by an orthopantomogram (OPG) system using Geant4 simulation toolkit. Recently, researchers have been trying to find an alternative material to the lead thyroid shield so that the OPG image has minimal metal artifacts.
View Article and Find Full Text PDFPhys Med Biol
January 2025
Laboratory for Biomaterials in Imaging (BIM), Axe Oncologie, Centre Hospitalier Universitaire (CHU) de Québec-Université Laval, 2705, boul. Laurier (T1-61a), Québec, G1V 4G2, Canada.
Biodegradable cardiovascular stents made of thin, low atomic number metals (e.g. Zn, Mg, Fe) are now approved for clinical use.
View Article and Find Full Text PDFJ Radiol Prot
December 2024
Department of Optometry, Radiography and Lighting Design, University of South-Eastern Norway (USN), Drammen, Norway.
Radiat Prot Dosimetry
November 2024
Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Hocho, Hirosaki, Aomori 036-8564, Japan.
Surface collection efficiency (SCE) of a cellulose membrane filter (CMF) and a cellulose-glass fiber filter used in environmental monitoring for alpha-emitting radionuclides from nuclear facilities and natural radioactivity sources was evaluated for particles in the size range of 0.03-0.1 μm at different levels of face velocity.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Medical Imaging, Radboud University Medical Center, Nijmegen, The Netherlands.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!