Objectives: To compare polytetrafluorethylene (PTFE) and polyester grafts (Dacron) for above knee femoropopliteal bypass.

Design: Multicenter randomised clinical trial.

Material And Methods: 427 patients were randomised between 6mm Dacron (Uni-Graft, B. Braun Melsungen AG, 34212 Melsungen, Germany) and PTFE (Goretex, W. L. Gore & Ass. Inc., Newark DE 19711, USA) above-knee femoropopliteal bypass grafts within 13 centres in Denmark (n=261), Norway (n=113) & Finland (n=53) between 1993 and 1998. Fourteen (3%) patients were excluded, leaving 413 patients with 208 Dacron and 205 PTFE grafts for analysis. Age, gender, indication (claudication: 65%), run-off (2 or 3 vessels: 76%), diabetes (17%) and hypertension (31%) as well as cerebrovascular (9%) and cardiac (33%) risks were evenly distributed. Patients were followed postoperatively at 1, 12 and 24 months. Patency assessment was based on ankle-brachial pressures or imaging in case of doubt.

Results: The two-year primary patency rates for Dacron and PTFE were 70% and 57% (p=0.02), whereas the secondary patency rates were 76% and 65% (p=0.04), respectively. Primary patency at two years was significantly influenced by the number of patent crural vessels (two or three 67%, one 50%, p=0.01). Amputations at two years, major in 4% and minor in 3%, 30-days mortality and complications (wound infections: 3% and other wound complications: 13%) occurred equally frequent in both groups. At two years, patients treated for critical limb ischemia had a major amputation more often than patients operated on for intermittent claudication, 10 and 3 respectively (p=0.003), and had higher mortality rates, 20% and 8% respectively (p=0.001).

Conclusion: This trial confirms that Dacron is at least as durable as PTFE for above-knee bypass procedures, and might even be superior.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejvs.2007.01.016DOI Listing

Publication Analysis

Top Keywords

dacron ptfe
8
ptfe above-knee
8
above-knee femoropopliteal
8
femoropopliteal bypass
8
multicenter randomised
8
primary patency
8
patency rates
8
dacron
6
patients
6
ptfe
5

Similar Publications

Article Synopsis
  • The study investigates alternative graft options for infrainguinal bypass surgery in patients with chronic limb-threatening ischemia, as the ideal graft (great saphenous vein) is often unavailable.
  • Data from the Vascular Quality Initiative database was analyzed, categorizing patients into three graft groups: arm vein grafts (AVs), prosthetic grafts (PGs), and biologic grafts (BGs), while excluding saphenous vein grafts.
  • Results show that patients with PGs had a higher risk of infections and 1-year mortality than those with AVs, while BGs were associated with increased risks of graft occlusion, infection, and higher chances of both mortality and amputation compared to both AVs and PG
View Article and Find Full Text PDF
Article Synopsis
  • Vascular injuries, while rare, can significantly increase short-term and long-term risks during elective abdominal or pelvic surgeries, leading to serious complications such as occlusion or dissection.
  • A study analyzed cases from January 2018 to July 2023, involving 72 patients who experienced iatrogenic vascular injuries during surgery, with the majority undergoing gynecologic and urologic procedures.
  • The treatment approaches included various surgical methods like embolectomy and anastomosis, and despite complications in a small number of patients, there were no reported deaths during hospitalization or within 30 days post-surgery.
View Article and Find Full Text PDF
Article Synopsis
  • This study investigated the occurrence of branch thrombosis in patients treated for aortic arch issues using an arch branched device (ABD), focusing on how clinical and geometric factors may influence this risk.
  • Out of 39 patients, thrombus formation was observed in 10% of branches, primarily associated with specific measurements like wider stent diameters and higher body mass index (BMI).
  • Overall, the technical success of the procedure was high at 97%, but there were notable rates of serious adverse events, early and late mortality, and stroke following the treatment.
View Article and Find Full Text PDF

There is a lack of agreement on a suitable container material for per- and polyfluoroalkyl substances (PFAS) analysis, particularly at trace levels. In this study, the losses of 18 short- and long-chain (C4-C10) PFAS to commonly used labware materials (high-density polyethylene (HDPE), polypropylene (PP), polystyrene (PS), polypropylene co-polymer (PPCO), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), and glass were investigated. The influence of sample storage and preparation conditions, i.

View Article and Find Full Text PDF

Purpose: This study aimed to assess the feasibility and short-term outcomes of different manufactured proximal and distal stent graft components during fenestrated endovascular aortic repair (FEVAR).

Materials And Methods: A multicenter retrospective review was conducted at 3 aortic centers, involving all consecutive patients who underwent FEVAR utilizing a customized Dacron-based tubular proximal and a distal bifurcated polytetrafluoreten (PTFE)-based commercially available stent grafts. Primary outcomes were 30 day mortality, major adverse events, and technical and clinical success.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!