Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To investigate the biomechanic influence of triple-stranded sutures and the spatial arrangement of the strands on the strength of the 6-strand Pennington modified Kessler repair.
Methods: In the present ex vivo study of pig extensor tendons 2 techniques were used: (1) triple-stranded suture (3 suture strands in the same needle) and (2) triple-stranded bound suture (3 suture strands in the same needle that were bound together, parallel to each other, side by side). The repairs were subjected to static tensile testing.
Results: The 6-strand modified Kessler repair performed with triple-stranded bound suture reached significantly higher yield force, ultimate force, and both partial and total 1-, 2-, and 3-mm gap forces compared with the repairs performed with triple-stranded suture. The stiffness and strain values at the yield point and at the ultimate point did not differ significantly.
Conclusions: This experimental study introduces a way to improve the strength of the tendon repair. The triple-stranded bound suture significantly increased both the gap resistance and ultimate force of the 6-strand modified Kessler repair. We assume the improvements are due to increased holding capacity of the locking loops. The triple-stranded bound suture is easy to use and avoids several problems associated with traditional multistrand repairs. Further studies are needed before clinical use can be considered.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jhsa.2007.01.010 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!