A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Tribological investigation of novel HDPE-HAp-Al2O3 hybrid biocomposites against steel under dry and simulated body fluid condition. | LitMetric

Tribological investigation of novel HDPE-HAp-Al2O3 hybrid biocomposites against steel under dry and simulated body fluid condition.

J Biomed Mater Res A

Department of Materials and Metallurgical Engineering, Indian Institute of Technology, IIT-Kanpur, Kanpur 208016, India.

Published: October 2007

Among various biocompatible polymers, polyethylene based materials have received wider attention because of its excellent stability in body fluid, inertness, and easy formability. Attempts have been made to improve their physical properties (modulus/strength) to enable them to be used as load bearing hard tissue replacement applications. Among such attempts, high density polyethylene (HDPE)-hydroxyapatite (HAp) composite (HAPEX), has already been developed for total hip replacement (THR) acetabular cup and low load bearing bone tissue replacement. In the present work, alumina has been added as a partial replacement of HAp phase to improve the mechanical and tribological properties of the HAPEX composite. In an attempt to assess the suitability of the developed composite in THR application, the tribological properties against steel counterbody under both in air and simulated body fluid (SBF), have been investigated and efforts have been made to understand the wear mechanisms. The fretting wear study indicates the possibility of achieving extremely low COF (Coefficient of Friction approximately 0.09) as well as higher wear resistance (order of 10(-6) mm(3)/N m) with the newly developed composites in SBF. A low wear depth of approximately 4.6-5.3 microm is recorded, irrespective of fretting environment. The implication of the work is that optimal and combined addition of bioactive and bioinert ceramic filler to HDPE can provide a good opportunity to obtain hybrid biocomposites with better combination of physical properties (modulus, hardness) as well as low friction and high wear resistance.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.a.31203DOI Listing

Publication Analysis

Top Keywords

body fluid
12
hybrid biocomposites
8
simulated body
8
physical properties
8
load bearing
8
tissue replacement
8
tribological properties
8
wear resistance
8
wear
5
tribological investigation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!