Study of an axial flow cyclone to remove nanoparticles in vacuum.

Environ Sci Technol

Institute of Environmental Engineering, National Chiao Tung University, no. 75 Poai Street, Hsin Chu, 300, Taiwan.

Published: March 2007

An axial flow cyclone for removing nanoparticles was tested for collection efficiency. Data were validated numerically in vacuum conditions of several Torrs, with flow rates of 0.35-0.57 slpm. The experimental cutoff aerodynamic diameter of the cyclone ranged from 21.7 to 49.8 nm. A 3-D numerical simulation was conducted first to calculate detailed flow and pressure fields, then a Brownian Dynamics simulation was done to determine the collection efficiency of nanoparticles. Both centrifugal force and Brownian diffusion were taken into account. The simulated results for both pressure drop and cutoff aerodynamic diameter are in good agreement with the experimental data. In comparison, previous theories using simplified tangential flow field assumption are not able to predict collection efficiencies accurately. The numerical model developed in this study can facilitate cyclone design to classify valuable nanopowders below a certain diameter, or to remove toxic nanoparticles from the vacuum exhaust of process chambers commonly used in high-tech industries.

Download full-text PDF

Source
http://dx.doi.org/10.1021/es060518oDOI Listing

Publication Analysis

Top Keywords

axial flow
8
flow cyclone
8
nanoparticles vacuum
8
collection efficiency
8
cutoff aerodynamic
8
aerodynamic diameter
8
flow
5
study axial
4
cyclone
4
cyclone remove
4

Similar Publications

Advancement of the Dragon Heart 7-Series for Pediatric Patients With Heart Failure.

Artif Organs

January 2025

BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA.

Background: Safe and effective pediatric blood pumps continue to lag far behind those developed for adults. To address this growing unmet clinical need, we are developing a hybrid, continuous-flow, magnetically levitated, pediatric total artificial heart (TAH). Our hybrid TAH design, the Dragon Heart (DH), integrates both an axial flow and centrifugal flow blood pump within a single, compact housing.

View Article and Find Full Text PDF

Magnetic Induction Phase Difference for Cerebral Hemorrhage Detection.

Sensors (Basel)

December 2024

Department of Biomedical Engineering, Army Medical University, The Third Military Medical University, Chongqing 400038, China.

Magnetic induction phase shift is a promising technology for the detection of cerebral hemorrhage, owing to its nonradioactive, noninvasive, and real-time detection properties. To enhance the detection sensitivity and linearity, a zero-flow sensor was proposed. The uniform primary magnetic field and its counteraction were achieved.

View Article and Find Full Text PDF

The cavitation water jet cleaning and coating removal technique represents an innovative sustainable method for cleaning and removing coatings, with the nozzle serving as a crucial component of this technology. Developing an artificially submerged nozzle with a reliable structure and excellent cavitation performance is essential for enhancing cavitation water jets' cleaning and coating removal efficacy in an atmosphere environment (non-submerged state). This study is based on the shear flow cavitation mechanism of an angular nozzle, the resonance principle of an organ pipe, and the jet pump principle.

View Article and Find Full Text PDF

Through the ferrite single-phase parameters of M50 bearing steel obtained based on nanoindentation experiments and the representative volume element (RVE) model established based on the real microstructure of M50, this paper established a multiscale finite element model for the cold ring rolling of M50 and verified its accuracy. The macroscale and mesoscale flow behaviors of the ring during the cold rolling deformation process were examined and explained. The macroscopic flow behavior demonstrated that the stress distribution was uniform following rolling.

View Article and Find Full Text PDF

High-resolution hemodynamic estimation from ultrafast ultrasound image velocimetry using a physics-informed neural network.

Phys Med Biol

January 2025

The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of life Science and Technology, Xi'an Jiaotong University, Xi'an, People's Republic of China.

Estimating the high-resolution (HR) blood flow velocity and pressure fields for the diagnosis and treatment of vascular diseases remains challenging.. In this study, a physics-informed neural network (PINN) with a refined mapping capability was combined with ultrafast ultrasound image velocimetry (u-UIV) to predict HR hemodynamic parameters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!