Purpose: To evaluate the clinical performance of two daily disposable contact lenses: 1-DAY ACUVUE (1DA) (etafilcon A, Johnson & Johnson Vision Care) and FOCUS DAILIES with AquaComfort (FD) (nelfilcon A, CIBA Vision, Inc.), which contains a quickly released moisture enhancing agent, polyvinyl alcohol (PVA).
Methods: This was a 1-week, daily wear, subject-masked, bilateral, parallel group study with subjects randomly assigned to one of two daily disposable soft contact lenses. Subjects were existing soft contact lens wearers in the age range 18-39 years with a spherical refraction between -0.50 and -6.00 D. Subjects were assessed at baseline and after 1 week. Assessments included both subjective (symptoms, wearing time, vision) and objective (lens fit and ocular health) outcomes.
Results: Twenty clinical sites enrolled 282 subjects (74% female) of whom 276 (98%) successfully completed the study. Significantly more 1DA wearers reported higher mean comfort scores than with FD (3.95 versus 3.41, respectively, P<0.0001). End-of-day comfort means were also significantly higher with the 1DA group compared to the FD group (3.3 versus 3.0, P=0.03). The 1DA group reported significantly longer mean overall wearing time (1DA was worn on average 0.66+/-0.30 h longer than FD, P=0.03) and longer mean comfortable wearing time (1DA was worn on average 1.73+/-0.35 h longer than FD, P<0.0001). The 1DA lens generally showed significantly better on-eye fitting in terms of movement in primary (P<0.0001) and upgaze (P<0.0001) and ease of removal from the eye (92% versus 63%, P<0.0001) compared to FD. There was significantly less corneal staining observed with the 1DA wearing eyes compared with the FD wearing eyes (23% versus 45%, respectively, P<0.0001). Finally, there was a weak correlation between corneal staining and comfort for FD (r=0.27, P=0.002, n=136), but not for 1DA (r=-0.11, P=0.18, n=140).
Conclusion: Subjective and objective clinical performance differences between two commonly used daily disposable lenses highlight that, although both lenses may be considered as clinically acceptable, these lenses should not be regarded as interchangeable.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clae.2007.02.004 | DOI Listing |
Addiction
January 2025
Department of Behavioural Science and Health, University College London, London, UK.
Background/aims: E-cigarettes are frequently used by people who smoke. This study measured how the prevalence and patterns of smoking and vaping ('dual use') in England have changed as the vaping market has rapidly evolved.
Design: Representative monthly cross-sectional survey, July 2016 to April 2024.
Front Public Health
January 2025
School of Health Care Security, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, China.
Objective: In order to reduce the price and increase the accessibility of innovative medicines, China has implemented the National Drug Price Negotiation (NDPN) since 2016. Anticancer drug is the largest category of NDPN and the number continue to increase. This study evaluated the impact of this policy on the price, utilization rate and affordability of anticancer drugs based on the experiences of Shandong province.
View Article and Find Full Text PDFOphthalmic Physiol Opt
January 2025
School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia.
Purpose: To assess the repeatability of lipid layer thickness (LLT) measurement using the LipiView® interferometer after daily disposable contact lens (CL) wear and correlation with ocular comfort in soft contact lens wearers.
Methods: A prospective study was conducted over two consecutive months, wherein CL wearers (n = 20) wore either Somofilcon A or Verofilcon A daily disposable CLs in a crossover design, switching lenses after 1 month. The pre-corneal tear film LLT was measured at the end of each month after CLs had been worn for at least 6 h.
Lancet Respir Med
January 2025
Division of Respiratory Medicine and Gastroenterology, University of Dundee, Ninewells Hospital and Medical School, Dundee, UK. Electronic address:
Background: Bronchiectasis is a disease with a global impact, but most published data come from high-income countries. We aimed to describe the clinical characteristics of patients with bronchiectasis in China.
Methods: The Chinese Bronchiectasis Registry (BE-China) is a prospective, observational cohort enrolling patients from 111 hospitals in China.
Clin Exp Optom
January 2025
Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Manchester, UK.
Clinical Relevance: Knowledge of contact lens prescribing trends can (a) assist practitioners to benchmark their own prescribing habits, (b) help the contact lens industry understand preferred products, and (c) support academics in scholarly writings.
Background: This work aims to document contact lens prescribing trends in Australia over the past quarter of a century.
Methods: An annual survey of contact lens prescribing trends was conducted in Australia each year from 2000 to 2024, inclusive, by asking optometrists to provide information relating to 10 consecutive contact lens fits undertaken between January and March.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!