Brachytherapy dosimetry parameters calculated for a 131Cs source.

Med Phys

Department of Radiation Oncology, Tufts-New England Medical Center Tufts University School of Medicine, Box #246, 750 Washington Street, Boston, Massachusetts 02111, USA.

Published: February 2007

A comprehensive analysis of the IsoRay Medical model CS-1 Rev2 131Cs brachytherapy source was performed. Dose distributions were simulated using Monte Carlo methods (MCNP5) in liquid water, Solid Water, and Virtual Water spherical phantoms. From these results, the in-water brachytherapy dosimetry parameters have been determined, and were compared with those of Murphy et al. [Med. Phys. 31, 1529-1538 (2004)] using measurements and simulations. Our results suggest that calculations obtained using erroneous cross-section libraries should be discarded as recommended by the 2004 AAPM TG-43U1 report. Our Mclambda value of 1.046+/-0.019 cGy h(-1) U(-1) is within 1.3% of that measured by Chen et al. [Med. Phys. 32, 3279-3285 (2005)] using TLDs and the calculated results of Wittman and Fisher [Med. Phys. 34, 49-54 (2007)] using MCNP5. Using the discretized energy approach of Rivard [Appl. Radiat. Isot. 55, 775-782 (2001)] to ascertain the impact of individual 131Cs photons on radial dose function and anisotropy functions, there was virtual equivalence of results for 29.461< or =Egamma< or = 34.419 keV and for a mono-energetic 30.384 keV photon source. Comparisons of radial dose function and 2D anisotropy function data are also included, and an analysis of material composition and cross-section libraries was performed.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.2432162DOI Listing

Publication Analysis

Top Keywords

[med phys
12
brachytherapy dosimetry
8
dosimetry parameters
8
cross-section libraries
8
radial dose
8
dose function
8
function anisotropy
8
parameters calculated
4
calculated 131cs
4
131cs source
4

Similar Publications

Purpose: The purpose of this study was to establish a dosimetric correlation between the bladder volume and its effects on the dose received by the organs at risk (OARs) (urinary bladder, rectum, and sigmoid) during computed tomography (CT)-guided high-dose-rate (HDR) brachytherapy in carcinoma cervix, and to determine an optimum bladder volume to limit the dose to OARs.

Material And Methods: Seventy-five intracavitary applications in patients of carcinoma cervix (stage IIB, IIIA, IIIB, IVA) treated with external beam radiotherapy with concurrent chemotherapy followed by CT-based HDR intracavitary brachytherapy (tandem and ovoid type) at our institute between July 2014 to January 2016 were studied. The bladder volume at the time of imaging was noted and was correlated with the radiation dose received by bladder, rectum, and sigmoid colon.

View Article and Find Full Text PDF

Diffusion tensor imaging of brain white matter in Huntington gene mutation individuals.

Arq Neuropsiquiatr

August 2017

Universidade Federal de São Paulo, Escola Paulista de Medicina, Disciplina de Neurologia, São Paulo SP, Brasil.

Article Synopsis
  • The study aims to assess how white matter tracts are affected in patients with huntingtin gene mutations as a potential indicator of disease progression.
  • It involved 34 participants, with methods including brain MRI and diffusion tensor imaging to measure white matter integrity.
  • Results showed significant reductions in fractional anisotropy (indicating degeneration) in symptomatic Huntington's patients, but no differences were found between presymptomatic individuals and controls, highlighting the need for more research.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!