Determination of poorly fluorescent carbamate pesticides in water, bendiocarb and promecarb, using cyclodextrin nanocavities and related media.

Anal Chim Acta

Instituto de Investigaciones en Físico Química de Córdoba, Departamento de Química Orgánica, Facultad de Ciencias Químicas, Universidad Nacional de Córdoba, Ciudad Universitaria, 5000 Córdoba, Argentina.

Published: January 2007

The effect of native cyclodextrins (alpha, beta, or gammaCD with six, seven and eight glucose units, respectively), hydroxypropyl-beta-cyclodextrin (HPCD), chitosan (CHT) and glucose in water solution or water with n-propylamine (PA) as co-solvent upon the UV-vis and fluorescence properties of poorly fluorescent N-methyl carbamates pesticides (C) as bendiocarb (2,2-dimethyl-1,3-benzodioxol-4-ol methylcarbamate, BC) and promecarb (3-methyl-5-(1-methylethyl)phenol methylcarbame, PC) was examined. Fluorescent enhancement was found for both substrates with all CDs in water or PA-water except from PC with alphaCD. The addition of CHT increases the fluorescence of BC but decreases the fluorescence of PC, and glucose addition gives in both cases no spectral changes. Host-guest interaction was clearly determined by fluorescence enhancement with betaCD and HPCD with a 1:1 stoichiometry for the complexes (C:CD). The values obtained for the association constants (K(A), M(-1)) were (6+/-2)x10(2) and (2.3+/-0.3)x10(2) for BC:betaCD and BC:HPCD complexes, respectively. For PC:betaCD and PC:HPCD the values of K(A) were (19+/-2)x10(2) and (21+/-2)x10(2), respectively. The ratio of the fluorescence quantum yields for the bound and free substrates (phi(CCD)/phi(C)) was in the range 1.74-3.8. The limits of detection (L(D), microg mL(-1)) for the best conditions were (0.57+/-0.02) for BC with HPCD and (0.091+/-0.002) for PC with betaCD in water. Application to the analysis in pesticide spiked samples of tap water and fruit yields satisfactory apparent recoveries (84-114%), and for the extraction procedure in fruits and a commercial formulation, recoveries were of 81-98% and 104%, respectively. The method is rapid, simple, direct, sensitive and useful for pesticide analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2006.10.010DOI Listing

Publication Analysis

Top Keywords

water
6
fluorescence
5
determination fluorescent
4
fluorescent carbamate
4
carbamate pesticides
4
pesticides water
4
water bendiocarb
4
bendiocarb promecarb
4
promecarb cyclodextrin
4
cyclodextrin nanocavities
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!