Production of artifact methylmercury (MeHg(+)) during the analysis of two certified reference sediments, CRM-580 and IAEA-405, was investigated. Leaching of the analyte from the solid sample was achieved by ultrasound assisted acidic extraction. The aqueous leachate was either ethylated (NaBEt(4)) or phenylated (NaBPh(4)) using acetic/acetate or citric/citrate to buffer the solution. Preconcentration of the volatile compounds was carried out by extraction with an organic solvent (n-hexane) or solid phase microextraction (SPME). MeHg(+) was finally separated and detected by gas chromatography with atomic emission or mass spectrometry detection (GC-MIP-AED or GC-MS). In all the cases the concentrations obtained for MeHg(+) in the CRM-580 were significantly higher than the certified value. For the IAEA-405, however, the MeHg(+) concentration found was always statistically indistinguishable from the certified value. Experiments were also conducted with synthetic samples, such as aqueous mixtures of MeHg(+) and inorganic mercury (Hg(2+)) or silica-gel spiked with both compounds. The methylation rates found (defined as the percentage of Hg(2+) present in the sample which methylates to give artifact MeHg(+)) ranged from not observable (in certain synthetic aqueous mixtures) to 0.57% (analysis of CRM-580 under certain conditions). As the amount of Hg(2+) available in the sample seems to be the main factor controlling the magnitude of the artifact, several experiments were conducted using an ionic exchange resin (Dowex M-41) in order to minimise the concentration of this chemical in the reaction medium. First, a hydrochloric leachate of the sample was passed through a microcolumn packed with the exchanger. Second, the resin was mixed with the sample prior to extraction with HCl. In both cases, the predominant Hg(2+) species, HgCl(4)(2-), was adsorbed on the resin, whereas MeHg(+), mainly as MeHgCl, remained in solution. Following the second option, a new method to analyse MeHg(+) in conflictive matrices like certain sediments was proposed. This approach produced better results for the CRM-580, but a MeHg(+) concentration slightly, but statistically significant, higher than the reference value was still obtained.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2006.08.051DOI Listing

Publication Analysis

Top Keywords

mehg+
9
production artifact
8
artifact methylmercury
8
analysis certified
8
certified reference
8
reference sediments
8
ionic exchange
8
mehg+ concentration
8
concentration statistically
8
experiments conducted
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!