A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Combining high-performance liquid chromatography with on-line microdialysis sampling for the simultaneous determination of ascorbyl glucoside, kojic acid, and niacinamide in bleaching cosmetics. | LitMetric

We have used on-line microdialysis sampling coupled with high-performance liquid chromatography and UV-vis detection to simultaneously determine the contents of ascorbyl glucoside (AA-2G), kojic acid (KA), and niacinamide (VitB(3)) in commercial bleaching cosmetics. Our results indicate that AA-2G, KA, and VitB(3) separated well within 4.5 min on a reverse-phase Hypersil Fluophase PFP column when eluting with 0.020 M phosphate buffer solution in 40% (v/v) methanol at pH 5.5. The calibration curves were linear over the ranges 0.068-304, 0.071-284, and 0.024-488 microg mL(-1) for AA-2G, KA, and VitB(3), respectively, with correlation coefficients for the linear regression analyses falling within the range 0.9982-0.9999. The detection limits for AA-2G, KA, and VitB(3) were 0.01, 0.01, and 0.007 microg mL(-1), respectively. The detection wavelength was robust when the levels of the analytes in the samples were high (0.1-2%). The analytes were all detected using ultraviolet light (254 nm). The compounds diffuse through the membrane more readily when KA and VitB(3) are in their molecular forms and AA-2G is ionized. The recoveries were in the range 92-106% with good reproducibility (R.S.D.=3.9-8.7%). We used this procedure to assay six commercially available bleaching cosmetics; our results confirmed not only the precision of the method but also the claims made on the labels of the cosmetics. This approach provides a very simple means to determine the contents of AA-2G, KA, and VitB(3) in various dosages in bleaching cosmetics.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2006.08.002DOI Listing

Publication Analysis

Top Keywords

bleaching cosmetics
16
aa-2g vitb3
16
high-performance liquid
8
liquid chromatography
8
on-line microdialysis
8
microdialysis sampling
8
ascorbyl glucoside
8
kojic acid
8
acid niacinamide
8
determine contents
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!