Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Fluorescence in situ hybridization (FISH) provides an important adjunct to conventional cytogenetics and molecular studies in the evaluation of chromosome abnormalities associated with hematologic malignancies. FISH employs DNA probes and methods that are generally not Food and Drug Administration-approved, and therefore, their use as analyte-specific reagents involves unique pre- and postanalytical requirements. We provide an overview of the technical parameters influencing a reliable FISH result and encourage laboratories to adopt specific procedures and policies in implementing metaphase and interphase FISH testing. A rigorous technologist training program relative to specific types of probes is detailed, as well as guidance for consistent interpretation of findings, including typical and atypical abnormal results. Details are provided on commonly used dual-fusion, extra signal, and break-apart probes, correct FISH nomenclature in the reporting of results, and the use of FISH in relation to other laboratory testing in the ongoing monitoring of disease. This article provides laboratory directors detailed guidance to be used in conjunction with existing regulations to successfully implement a FISH testing program or to assess current practices, allowing for optimal clinical testing for patient care.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1867444 | PMC |
http://dx.doi.org/10.2353/jmoldx.2007.060128 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!