We describe a case of primary cardiac lymphoma diagnosed by transvenous biopsy under fluoroscopic and transthoracic echocardiographic guidance. A 38-year-old man was admitted because of exertional dyspnea. ECG revealed complete atrioventricular block. Transthoracic echocardiography revealed a large mass attached to the interventricular septum and protruding into the right atrium. The patient underwent a right heart catheterization and a biopsy was taken from the mass using fluoroscopic and transthoracic echocardiographic guidance. Diagnosis of malignant lymphoma was established by the biopsy specimen. The use of transthoracic echo in conjunction with fluoroscopy may be useful for the diagnosis of intracardiac mass transvenously.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2006.12.039DOI Listing

Publication Analysis

Top Keywords

fluoroscopic transthoracic
12
transthoracic echocardiographic
12
echocardiographic guidance
12
primary cardiac
8
cardiac lymphoma
8
heart catheterization
8
catheterization biopsy
8
biopsy fluoroscopic
8
transthoracic
5
diagnosis primary
4

Similar Publications

Percutaneous balloon pericardiotomy (PBP) has emerged as a less invasive alternative to surgical interventions for recurrent severe pericardial effusion (PE), particularly in patients with malignancies. This study evaluates the safety and efficacy of PBP in patients with recurrent severe PE. A total of 42 patients with recurrent severe PE underwent PBP between March 2008 and July 2024.

View Article and Find Full Text PDF

Echocardiography-guided percutaneous closure of oval-shaped secundum atrial septal defects.

BMC Cardiovasc Disord

October 2024

Division of Pediatric Cardiology and Congenital Heart Disease, Department of Cardiology and Vascular Medicine, National Cardiovascular Center Harapan Kita, Universitas Indonesia, Jakarta, Indonesia.

Background: An atrial septal defect (ASD) is considered oval-shaped when its shortest diameter is less than 75% of the longest diameter. Research on percutaneous closure of oval-shaped ASDs is limited, with no known reports of non-fluoroscopic closure for this population.

Objective: To assess the effectiveness of non-fluoroscopic percutaneous closure for oval-shaped ASDs.

View Article and Find Full Text PDF

Successful Transvenous Extraction of Adult Parasites from a Naturally Infected Domestic Ferret ().

Animals (Basel)

August 2024

Internal Medicine, Faculty of Veterinary Medicine, Research Institute of Biomedical and Health Sciences (IUIBS), University of Las Palmas de Gran Canaria, 35016 Las Palmas de Gran Canaria, Spain.

Heartworm disease caused by is a serious and underdiagnosed cardiovascular condition in domestic ferrets. Hemodynamic changes caused by parasitization in ferrets cause a potentially fatal syndrome, but its clinical findings and treatment have not yet been standardized. The objective of this study was to describe the clinical case of a successful surgical extraction in a ferret infected by .

View Article and Find Full Text PDF

The Impella CP is a percutaneously inserted temporary left ventricular assist device used in clinical practice and in translational research into cardiogenic shock, perioperative cardiac surgery, acute cardiac failure and mechanical circulatory support. Fluoroscopic guidance is usually used for insertion of an Impella, thus limiting insertion to within catheterization laboratories. Transthoracic, transoesophageal and intracardiac echocardiography have been reported to guide Impella CP implantation with identified specific limitations stemming from the surgical, anatomical and equipment factors.

View Article and Find Full Text PDF

Feasibility of a Percutaneous and Non-Fluoroscopic Procedure for Transcatheter Mitral Valve Edge-to-Edge Repair.

Rev Cardiovasc Med

December 2023

Department of Structural Heart Disease, National Center for Cardiovascular Disease, China & State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, 100037 Beijing, China.

Background: Transcatheter edge-to-edge repair (TEER) of the mitral valve has emerged as an alternative treatment for mitral regurgitation (MR). However, the high radiation exposure during the process has been associated with multiple adverse effects for medical staff. In this study, we assessed the feasibility and safety of TEER performed solely under the echocardiographic (echo) guidance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!