Aim: The aim of the present study was to investigate right ventricular (RV) myocardial textural properties in asymptomatic and symptomatic mitral stenosis (MS) patients with normal RV systolic function using integrated backscatter (IBS).
Methods: The study included 40 patients with MS of moderate or severe degree. Patients were classified into 2 groups according to NYHA class (asymptomatic group, NYHA class I, symptomatic group, NYHA class II-III). RV pulsed-wave tissue Doppler imaging (TDI) and IBS analyses were performed in all patients. Isovolumic contraction time (IVCT), systolic wave velocity (S), isovolumic relaxation time (IVRT), early diastolic wave velocity (E), and late diastolic wave velocity (A) were measured by TDI. IBS amplitude (IB) and cyclic variation (CV) of the RV lateral wall in the parasternal long-axis view were measured by IBS. CV was calculated by subtracting systolic IB from diastolic IB.
Results: IVRT (54.2 +/- 11.9 ms versus 86.2 +/- 16.2 ms, P < 0.001) and A wave amplitude (10.2 +/- 2.1 cm/s versus 13.6 +/- 1.8 cm/s, P < 0.05) were higher whereas E wave amplitude (11.7 +/- 1.6 cm/s and 10.3 +/- 1.5 cm/s, P < 0.05) and E/A ratio (1.3 +/- 0.3 versus 0.7 +/- 0.1, P < 0.001) were lower in group 2. Symptomatic patients had a lower CV value of RV (9.5 +/- 3.4 dB versus 6.7 +/- 1.9 dB, P = 0.004). There was a positive correlation between CV and E/A (r = 0.964, P < 0.001)
Conclusion: Symptomatic isolated MS patients had RV echo texture changes and diastolic dysfunction in comparison to asymptomatic ones with similar mitral valve areas in the presence of normal RV systolic function. In isolated MS, both pulsed-wave TDI and IBS may aid in the detection of RV diastolic pathology.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1536/ihj.48.87 | DOI Listing |
J Chem Inf Model
January 2025
Dept. of Engineering, King's College London, London WC2R 2LS, U.K.
Permeability is a measure of the degree to which cells can transport molecules across biological barriers. Units of permeability are distance per unit time (typically cm/s), where accurate measurements are needed to define drug delivery in homeostasis and to model dysfunction occurring during disease. This perspective offers a set of community-led guidelines to benchmark permeability data across multidisciplinary approaches and different biological contexts.
View Article and Find Full Text PDFUltrasound J
January 2025
Faculdade de Medicina da Universidade de Lisboa, Lisbon, Portugal.
Background: There are significant discrepancies in the optic nerve sheath diameter (ONSD) reported in the literature. We aimed to determine the ultrasonographic imaging features of ONSD and ophthalmic vessels in a healthy population, using a standardized protocol, and to estimate the effect of demographics and positioning changes on imaging measurements.
Methods: We measured the mean values of the ONSD in supine and sitting position and the Doppler imaging parameters of the ophthalmic, central retinal and short posterior ciliary arteries.
JACC Clin Electrophysiol
December 2024
The Hull Family Cardiac Fibrillation Management Laboratory, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada.
Background: Conduction velocity (CV) is a measure of the health of myocardial tissue. It can be measured by taking differences in local activation times from intracardiac electrodes. Several factors introduce error into the measurement, among which ignoring the 3-dimensional aspect is a major detriment.
View Article and Find Full Text PDFACS Pharmacol Transl Sci
January 2025
Division of Applied Regulatory Science, Office of Clinical Pharmacology, Office of Translational Sciences, Center for Drug Evaluation and Research, United States Food and Drug Administration (FDA), Silver Spring, Maryland 20993, United States.
Current in vitro cell-based methods, relying on single cell types, have structural and functional limitations in determining lung drug permeability, which is a contributing factor affecting both local and systemic drug levels. To address this issue, we investigated a 3D human lung airway model generated using a cell culture insert, wherein primary human lung epithelial and endothelial cells were cocultured at an air-liquid interface (ALI). To ensure that the cell culture mimics the physiological and functional characteristics of airway tissue, the model was characterized by evaluating several parameters such as cellular confluency, ciliation, tight junctions, mucus-layer formation, transepithelial electrical resistance, and barrier function through assaying fluorescein isothiocyanate-dextran permeability.
View Article and Find Full Text PDFBackground Doxorubicin is an important drug used in the treatment of children with acute leukemia, and cardiotoxicity is the most serious complication due to its use. The cardiac dysfunction due to doxorubicin can be acute, early, or late. Echocardiography is a non-invasive tool and can be employed to detect clinical and subclinical cardiac dysfunction and plan treatment strategies accordingly.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!