A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Differences in polypropylene shrinkage depending on mesh position in an experimental study. | LitMetric

Background: Polypropylene (PP) mesh is one of the most frequent materials used in hernia repair. We have experimentally evaluated the shrinkage of PP mesh depending on the place of implantation.

Methods: In 15 New Zealand rabbits a muscular defect measuring 3 x 3 cm was created in both pararectal sides of the abdominal wall. The defect was repaired using a PP mesh measuring 5 x 3.5 cm that was placed in the right side in the sublay location and in the left side in the onlay location. Five animals were killed on the 30th, 60th, and 90th postoperative days. Macroscopic measurement and microscopic study of the prosthesis-host tissue interfaces were performed.

Results: One rabbit was killed because of severe infection in the onlay mesh. Another 2 infections were tolerated in the onlay mesh side. All the prostheses were integrated in the host tissue at death. In the macroscopic evaluation the mesh areas were reduced by 25.92% on the 30th day, by 28.67% on the 60th day, and by 29.02% on the 90th day. The mesh shrinkage was greater in the onlay group than in the sublay group at the 3 time intervals. More inflammatory leukocyte and mononuclear responses also were seen in the onlay group.

Conclusions: These observations support the theory of PP mesh shrinkage as a consequence of the incorporation of the biomaterial to the scarring tissue. This shrinkage is significantly more intense if the meshes are placed in the onlay position.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjsurg.2006.06.045DOI Listing

Publication Analysis

Top Keywords

mesh
9
onlay mesh
8
mesh shrinkage
8
onlay
6
shrinkage
5
differences polypropylene
4
polypropylene shrinkage
4
shrinkage depending
4
depending mesh
4
mesh position
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!