Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Acute and long-term success of catheter ablation of right ventricular outflow tract tachycardia (RVOT VT) may be limited by the inability to reproduce the arrhythmia at the time of activation (AM) and pace mapping (PM). We have observed early initiation of the clinical VT when subtherapeutic radiofrequency (RF) energy was applied to the target area (TA), defined as a 2-cm(2) area around a pace match. We describe a novel approach using thermal mapping (TM) to guide the ablation of RVOT VT.
Methods: Thirteen patients (10 female, mean age 46.2 +/- 13.7 years) with symptomatic VT of left bundle branch block (LBBB) inferior axis morphology and no structural heart disease underwent standard electrophysiologic evaluation with PM (n = 13), AM (n = 13), and 3D noncontact mapping (n = 4). Thermal mapping was performed after standard techniques failed to induce stable sustained VT for mapping in all 13 patients: RF was applied for 5-10 seconds in the TA to achieve a tip temperature of 45-50 degrees C. At sites where morphologically consistent with the clinical VT was induced, RF was applied at target temperature between 50 and 60 degrees C for 30-60 seconds. TM was repeated before and after intravenous Isoproterenol infusion until no further VT could be induced by low temperature application.
Results: Noninducibility was achieved in all 13 patients. During a mean follow-up of 29 months (9-69 months), all patients remain arrhythmia-free, off antiarrhythmic medications.
Conclusion: Thermal mapping is a safe and effective adjunctive technique for the mapping and ablation of RVOT VT when sustained tolerated clinical VT cannot be induced.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1540-8159.2007.00674.x | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!