Validation of Cosmed's FitMate in measuring exercise metabolism.

Res Sports Med

Department of Health, Leisure, and Exercise Science, Human Performance Lab, Appalachian State University, Boone, North Carolina 28608, USA.

Published: May 2007

The purpose of this study was to assess the validity of the FitMate metabolic system (Cosmed, Rome, Italy) in measuring oxygen consumption during graded exercise. The FitMate is a new, small (20 x 24 cm) metabolic analyzer designed for measurement of oxygen consumption during rest and exercise. Subjects included 40 healthy adults (N = 20 males, N = 20 females) ranging in age from 18 to 37 kg/m2 (mean +/- SD age, 22.5 +/- 3.6 years) and body mass index (BMI) from 18.3 to 32.5 kg/m2 (23.2 +/- 3.3 years). One-minute FitMate and Douglas bag measurements were made during steady state conditions at the end of each 3-minute stage of the Bruce treadmill graded exercise test, and subjects continued until they could not attain steady state exercise during a stage. Oxygen consumption difference scores (Douglas bag minus FitMate measurements) did not differ between males and females, so data were combined and analyzed for the entire group. During the first three stages, mean oxygen consumption did not differ significantly between the Douglas bag and FitMate systems (26.5 +/- 1.1 and 26.7 +/- 1.3 ml.kg-1.min-1, respectively, P = 0.140) with a mean absolute difference of 0.23 +/- 0.91 ml.kg-1.min-1 or 14.2 +/- 67.5 ml.min-1. In conclusion, the FitMate metabolic system accurately measures oxygen consumption during graded treadmill exercise when compared with the Douglas bag system in male and female adults.

Download full-text PDF

Source
http://dx.doi.org/10.1080/15438620601184380DOI Listing

Publication Analysis

Top Keywords

oxygen consumption
20
douglas bag
16
fitmate metabolic
8
metabolic system
8
consumption graded
8
graded exercise
8
males females
8
+/- years
8
steady state
8
fitmate
7

Similar Publications

Constipation is correlated with diminished cognitive function, revealing a possible rectum-brain connection. In this counter-balanced crossover trial, 13 elite triathletes underwent a Stroop test to assess cognitive function and executive control. The Stroop test was conducted both with and without magnesium oxide intake, with a 1-week washout period between sessions.

View Article and Find Full Text PDF

Diabetic retinopathy, a microvascular complication of diabetes, is the leading cause of blindness in adults, but the molecular mechanism of its development remains unclear. Retinal mitochondrial DNA is damaged and hypermethylated, and mtDNA-encoded genes are downregulated. Expression of a long noncoding RNA (larger than 200 nucleotides, which does not translate into proteins), encoded by mtDNA, cytochrome B (Lnc), is also downregulated.

View Article and Find Full Text PDF

The cardiovascular implications of thyroid disease have been recognized as one of the most characteristic signs that result from the effect of thyroid hormone (TH). Both hyperthyroidism and hypothyroidism produce changes in cardiac contractility, myocardial oxygen consumption, cardiac output, blood pressure, and systemic vascular resistance. The bradyarrhythmias, including atrioventricular block and sick sinus syndrome, are exceedingly rare in hyperthyroidism.

View Article and Find Full Text PDF

Oral Administration of Hydrogen-rich Water: Biomedical Activities, Potential Mechanisms, and Clinical Applications.

Curr Pharm Des

January 2025

Shandong Provincial Key Medical and Health Laboratory of Hydrogen Biomedical Research & Key Laboratory of Major Diseases and Hydrogen Medical Translational Applications in Universities of Shandong Province, Taishan Institute for Hydrogen Biomedical Research, The Second Affiliated Hospital of Shandong First Medical University, Tai'an, China.

Molecular hydrogen (H2) is considered a biological antioxidant. Hydrogen-rich Water (HRW) is regular water that contains dissolved H2 and has become more widely used in recent years. This review summarizes the basic research and clinical applications of HRW consumption to support its use for daily health and clinical treatment.

View Article and Find Full Text PDF

Maximal oxygen uptake (VOmax) in healthy subjects is primarily limited by systemic oxygen delivery. In chronic kidney disease (CKD), VOmax is potentially reduced by both central and peripheral factors. We aimed to investigate the effect on VOpeak of adding arm exercise to leg exercise.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!