[Simple self-correlative algebraic reconstruction technique].

Guang Pu Xue Yu Guang Pu Fen Xi

Department of Information Physics and Engineering, Science Institute, Nanjing University of Science and Technology, Nanjing 210094, China.

Published: December 2006

AI Article Synopsis

Article Abstract

A new improvement was brought forward in algebraic reconstruction technique (ART), named simple self-correlative algebraic reconstruction technique (SSCART), and its reconstructive result was discussed in detail. With numerical simulation technique, both ART and SSCART were numerically simulated with computer, and discussed in terms of simulated result and reconstructive accuracy with error indexes such as mean-square error (MSE), absolute value error (AVE) and peak error (PE). As a result, the accuracy of SSCART was markedly improved. Its MSE was decreased sixty-five percent compared to that of ART (the difference between MSE of ART and that of SSCART divided by the MSE of ART) at the level of 10(-4) magnitude, and PE decreased ninety-nine point nine percent at the level of 10 magnitude. The iterating program of SSCART was not a new program to ART, but only a simple factor was added to. SSCART was considered a superior reconstruction technique with many good virtues such as simple iterating program, persistent convergent iterating process, and high reconstructive accuracy. It is the most superior iterating reconstruction technique in current ARTs to our knowledge.

Download full-text PDF

Source

Publication Analysis

Top Keywords

reconstruction technique
16
algebraic reconstruction
12
self-correlative algebraic
8
technique art
8
art sscart
8
reconstructive accuracy
8
mse art
8
iterating program
8
art
6
sscart
6

Similar Publications

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Purpose: Precision medicine plays an important role in the treatment of patients with advanced melanoma. Despite its high incidence in White patients, advanced melanoma is rare in Asian countries, hampering prospective clinical trials targeting the Asian population. This retrospective study aimed to elucidate the real-world molecular diagnoses and outcomes of Japanese patients with melanoma using comprehensive genome profiling (CGP).

View Article and Find Full Text PDF

Motion-Compensated Multishot Pancreatic Diffusion-Weighted Imaging With Deep Learning-Based Denoising.

Invest Radiol

January 2025

From the Department of Radiology, Stanford University, Stanford, CA (K.W., M.J.M., A.M.L., A.B.S., A.J.H., D.B.E., R.L.B.); Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (K.W.); GE HealthCare, Houston, TX (X.W.); GE HealthCare, Boston, MA (A.G.); and GE HealthCare, Menlo Park, CA (P.L.).

Objectives: Pancreatic diffusion-weighted imaging (DWI) has numerous clinical applications, but conventional single-shot methods suffer from off resonance-induced artifacts like distortion and blurring while cardiovascular motion-induced phase inconsistency leads to quantitative errors and signal loss, limiting its utility. Multishot DWI (msDWI) offers reduced image distortion and blurring relative to single-shot methods but increases sensitivity to motion artifacts. Motion-compensated diffusion-encoding gradients (MCGs) reduce motion artifacts and could improve motion robustness of msDWI but come with the cost of extended echo time, further reducing signal.

View Article and Find Full Text PDF

The green seaweed relies on associated bacteria for morphogenesis and is an important model to study algal-bacterial interactions. -associated bacteria exhibit high turnover across environmental gradients, leading to the hypothesis that bacteria contribute to the acclimation potential of the host. However, the functional variation of these bacteria in relation to environmental changes remains unclear.

View Article and Find Full Text PDF

Background: Nipple-sparing mastectomy (NSM) has become increasingly popular in recent years. However, the impact of prepectoral versus subpectoral implant reconstruction on nipple position, clinical outcomes, and patient-reported outcomes (PROs) after NSM remains unknown.

Objective: We hypothesized that prepectoral reconstruction would lead to a more anatomic nipple position and improved clinical outcomes and PROs as compared to subpectoral reconstruction following NSM.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!