MDA improvement technique for lung counter measurements of uranium workers.

Radiat Prot Dosimetry

Nuclear Research Centre Negev, P.O.B. 9001, Beer-Sheva, 84190, Israel.

Published: September 2008

A practical and simple method was employed to improve the minimum detectable activity (MDA) for lung counting measurements by summing several accumulated spectra. The method was checked for natural uranium, which produces peaks due to photon energies of 63.3, 92.6 and 185.7 keV. By combining nine measurements, an overall improvement of the MDA by a factor of about 3 was achieved. Uranium contamination levels lower than the MDA of a single spectrum could be detected with acceptable accuracy when analyzing the sum spectra. Specific results are given for four workers occupationally exposed to natural uranium.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncm146DOI Listing

Publication Analysis

Top Keywords

natural uranium
8
mda
4
mda improvement
4
improvement technique
4
technique lung
4
lung counter
4
counter measurements
4
uranium
4
measurements uranium
4
uranium workers
4

Similar Publications

An activity concentration-based proposal for radon management in workplaces involving NORM in Canada.

Radiat Environ Biophys

December 2024

Radiation Protection Bureau, Health Canada, 775 Brookfield Road, Ottawa, ON, K1A 1C1, Canada.

The Canadian Guidelines for the Management of Naturally Occurring Radioactive Materials (NORM) have been developed to manage radiation doses received in workplaces involving NORM, such as mineral extraction and processing, oil and gas production, metal recycling or water treatment facilities. This management strategy works well for most naturally occurring radioactive materials in workplaces, with the exception of radon. Radon is a naturally occurring radioactive gas generated by the decay of uranium-bearing minerals in rocks and soils.

View Article and Find Full Text PDF

The primary approach to assessing monitored natural attenuation (MNA) is currently based on a conceptual model utilizing the total contaminant concentrations, assuming a single aqueous species. However, many contaminants, such as metals and radionuclide - including iodine, can exist in multiple species that behave chemically differently in the environment and can exist simultaneously. For example, radioiodine often occurs concurrently as three major aqueous species: iodide (I), iodate (IO), and organo-I, which undergo distinct attenuation pathways and exhibit markedly different mobility and geochemical behavior.

View Article and Find Full Text PDF

Within the framework of surface-adsorbate interactions relevant to chemical reactions of spent nuclear fuel, the study of actinide oxide systems remains one of the most challenging tasks at both the experimental and computational levels. Consequently, our understanding of the effect of their unique electronic configurations on surface reactions lags behind that of d-block oxides. To investigate the surface properties of this system, we present the first infrared spectroscopy analysis of carbon monoxide (CO) interaction with a monocrystalline actinide oxide, UO(111).

View Article and Find Full Text PDF

Radiological considerations in using uranium mine waste rock for road construction materials.

J Environ Radioact

January 2025

Health Physics Division, Bhabha Atomic Research Centre, Mumbai, 400085, India; Homi Bhabha National Institute, Anushakti Nagar, Mumbai, 400094, India.

India's road construction is vital for its infrastructure growth, requiring approximately 20,000 tons of high-quality aggregates per kilometer - materials that are increasingly scarce, leading to higher costs and delays. The industrial sector, a cornerstone of the Indian economy, also struggles with waste management. Earlier studies suggested that industrial waste can be used in road construction materials however, the radiological considerations were not focused.

View Article and Find Full Text PDF

Comprehensive determination of elements ranging from uranium to americium by hybrid measurement of fluorescent and spontaneously emitted characteristic X-rays.

Talanta

January 2025

National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Chiba, Chiba, 263-8555, Japan; Department of Physics, Faculty of Science, Toho University, 2-2-1 Miyama, Funabashi, Chiba, 274-8510, Japan.

Natural uranium isotopes have extremely long half-lives; therefore, analytical methods based on the number of atoms, such as X-ray fluorescence (XRF) analysis, are suitable for uranium detection. However, XRF measurements cannot be used to detect the major isotopes of americium when present in amounts barely detectable using radiation measurements, owing to their relatively short half-lives. Because of α-decay-induced internal conversion, where orbital electrons are emitted instead of γ-rays, these nuclides emit characteristic X-rays.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!