The role of NADPH oxidase (NOX) and the regulatory subunit p47(phox) for hypoosmotic ROS generation was studied in cultured rat astrocytes and brain slices of wilde type and p47(phox) knock-out mice. Cultured rat astrocytes express mRNAs encoding for the regulatory subunit p47(phox), NOX1, 2, and 4, and the dual oxidases (DUOX)1 and 2, but not NOX3. Hypoosmotic (205 mosmol/L) swelling of cultured astrocytes induced a rapid generation of ROS that was accompanied by serine phosphorylation of p47(phox) and prevented by the NADPH oxidase inhibitor apocynin. Apocynin also impaired the hypoosmotic tyrosine phosphorylation of Src. Both, hypoosmotic ROS generation and p47(phox) serine phosphorylation were sensitive to the acidic sphingomyelinase inhibitors AY9944 and desipramine, the protein kinase C (PKC)zeta-inhibitory pseudosubstrate peptide, the NMDA receptor antagonist MK-801 and the intracellular Ca(2+) chelator BAPTA-AM. Also hypoosmotic exposure of wilde type mouse cortical brain slices increased ROS generation, which was allocated in part to the astrocytes and which was absent in presence of apocynin and in cortical brain slices from p47(phox) knock-out mice. Also ammonia induced a rapid ROS production in cultured astrocytes and brain slices, which was sensitive to apocynin. The data suggest that astrocyte swelling triggers a p47(phox)-dependent NADPH oxidase-catalyzed ROS production. The findings further support a close interrelation between osmotic and oxidative stress in astrocytes, which may be relevant to different brain pathologies including hepatic encephalopathy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/glia.20504 | DOI Listing |
Cancers (Basel)
January 2025
Department of Neurosurgery, Río Hortega University Hospital, 47014 Valladolid, Spain.
Intraoperative ultrasound (ioUS) provides real-time imaging during neurosurgical procedures, with advantages such as portability and cost-effectiveness. Accurate tumor segmentation has the potential to substantially enhance the interpretability of ioUS images; however, its implementation is limited by persistent challenges, including noise, artifacts, and anatomical variability. This study aims to develop a convolutional neural network (CNN) model for glioma segmentation in ioUS images via a multicenter dataset.
View Article and Find Full Text PDFCancers (Basel)
January 2025
Department of Neurosurgery, Río Hortega University Hospital, 47014 Valladolid, Spain.
Background: Accurate prognostic models are essential for optimizing treatment strategies for glioblastoma, the most aggressive primary brain tumor. While other neuroimaging modalities have demonstrated utility in predicting overall survival (OS), intraoperative ultrasound (iUS) remains underexplored for this purpose. This study aimed to evaluate the prognostic potential of iUS radiomics in glioblastoma patients in a multi-institutional cohort.
View Article and Find Full Text PDFPLoS One
January 2025
Instituto de Microelectrónica de Sevilla (IMSE-CNM), Consejo Superior de Investigaciones Científicas (CSIC) and Universidad de Sevilla, Sevilla, Spain.
Epilepsy is a prevalent neurological disorder that affects approximately 1% of the global population. Approximately 30-40% of patients respond poorly to antiepileptic medications, leading to a significant negative impact on their quality of life. Closed-loop deep brain stimulation (DBS) is a promising treatment for individuals who do not respond to medical therapy.
View Article and Find Full Text PDFPediatr Radiol
January 2025
Research Department of Early Life Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, SE1 7EH, UK.
Background: Motion correction methods based on slice-to-volume registration (SVR) for fetal magnetic resonance imaging (MRI) allow reconstruction of three-dimensional (3-D) isotropic images of the fetal brain and body. However, all existing SVR methods are confined to research settings, which limits clinical integration. Furthermore, there have been no reported SVR solutions for low-field 0.
View Article and Find Full Text PDFTomography
January 2025
NextGen Precision Health, Department of Radiology, University of Missouri Columbia, 1030 Hitt Street, Columbia, MO 65201, USA.
: The increased SNR available at 7T combined with fast readout trajectories enables accelerated spectroscopic imaging acquisitions for clinical applications. In this report, we evaluate the performance of a Hadamard slice encoding strategy with a 2D rosette trajectory for multi-slice fast spectroscopic imaging at 7T. : Moderate-TE (~40 ms) spin echo and J-refocused polarization transfer sequences were acquired with simultaneous Hadamard multi-slice excitations and rosette in-plane encoding.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!