A sensitive bioanalytical method for the measurement of two major circulating metabolites of duloxetine [4-hydroxy duloxetine glucuronide (LY550408) and 5-hydroxy-6-methoxy duloxetine sulfate (LY581920)] in plasma is reported. This method produced acceptable precision and accuracy over the validation range of 1-1000 ng/mL. Several issues had to be addressed in order to develop an LC/MS/MS assay for these metabolites. First, 4-hydroxy duloxetine glucuronide required chromatographic resolution from the 5-, and 6-hydroxy duloxetine glucuronide isomers. Second, the glucuronide conjugate is readily ionized under positive ESI conditions, while the sulfate conjugate required negative ESI conditions to obtain adequate sensitivity. Finally, the chromatographic conditions needed to separate the glucuronide isomers were not suitable for the analysis of the sulfate conjugate. The present method addressed these challenges, and was successfully applied to multiple human pharmacokinetic studies in which subjects received oral doses of duloxetine hydrochloride.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2007.02.025DOI Listing

Publication Analysis

Top Keywords

duloxetine glucuronide
12
metabolites duloxetine
8
glucuronide isomers
8
esi conditions
8
sulfate conjugate
8
duloxetine
7
glucuronide
5
development validation
4
validation liquid
4
liquid chromatography-tandem
4

Similar Publications

To develop an LC-MS/MS method for simultaneous determination of duloxetine and its metabolite, 4-hydroxy duloxetine glucuronide (4HDG) in human plasma and to investigate the potential back-conversion of 4HDG to duloxetine using stability study. The LC-MS/MS method was validated according to the EMA and USFDA Bioanalytical Method Validation Guidelines and applied to pilot bioequivalence study. The method validation results were within the acceptance limits.

View Article and Find Full Text PDF

Objectives: Minimizing the impact of major or unstable metabolites on the determination of a drug substance represents a leading task in the development and validation of bioanalytical methods. "Incurred samples reanalysis" provides relevant information too late; therefore, carefully selected tests on known metabolites should precede the pharmacokinetic studies.

Design And Methods: This paper describes a simple and rapid HPLC-UV method for the determination of duloxetine, a potent serotonin and norepinephrine reuptake inhibitor, in the presence of its major metabolite, i.

View Article and Find Full Text PDF

The major metabolite of duloxetine is a glucuronide conjugate of 4-hydroxy duloxetine (4-HD). However, interestingly, there have been no reports determining concentrations of 4-HD and no fully validated method has been established for measuring duloxetine and 4-HD in rat plasma. We developed a method for the simultaneous quantification of duloxetine and its metabolite in rat plasma using high-performance liquid chromatography tandem mass spectrometry.

View Article and Find Full Text PDF

Gateways to clinical trials.

Methods Find Exp Clin Pharmacol

September 2007

Prous Science, Barcelona, Spain.

12B75, 274150; Abacavir sulfate/lamivudine, Abatacept, Ad2/HIF-1alpha, Adalimumab, Adefovir, Adefovir dipivoxil, AGN-201904-Z, AIDSVAX, Albinterferon alfa-2b, Alemtuzumab, Aliskiren fumarate, Alvimopan hydrate, Amlodipine besylate/atorvastatin calcium, Amlodipine besylate/Olmesartan medoxomil, Ammonium tetrathiomolybdate, Amodiaquine, Apaziquone, Aprepitant, Arsenic trioxide, Artesunate/Amodiaquine, Ascorbic acid, Atazanavir sulfate, Atazanavir/ritonavir, Atomoxetine hydrochloride, Atrigel-Leuprolide, Axitinib; Bevacizumab, Binodenoson, Bortezomib, Bovine lactoferrin; Calcipotriol/betamethasone dipropionate, Carisbamate, Certolizumab pegol, Ciclesonide, Conivaptan hydrochloride, CP-690550, CP-751871, Cypher; Dapivirine, Darbepoetin alfa, Darunavir, Dasatinib, del-1 Genemedicine, Denosumab, Desloratadine, Dexlansoprazole, DiabeCell, Drospirenone/ethinylestradiol, DTaP-HepB-IPV, Duloxetine hydrochloride, Dutasteride; Eculizumab, Eldecalcitol, Eletriptan, Emtricitabine, Entecavir, Eritoran tetrasodium, Ertapenem sodium, Escitalopram oxalate, Eslicarbazepine acetate, Esomeprazole magnesium, Estradiol acetate, Eszopiclone, ETEC vaccine, Etoricoxib, Exenatide, Ezetimibe; Fluticasone furoate, Fosmidomycin, Fosmidomycin/clindamycin; Glutamine; Heat Shock Protein 10, Hepatitis B hyperimmunoglobulin, HIV vaccine, Hochuekki-to, Human Albumin, Human papillomavirus vaccine; Immune globulin subcutaneous [human], IMP-321, Interferon omega, ISIS-301012, Istaroxime; Japanese encephalitis virus vaccine; Latanoprost/timolol maleate, Lenalidomide, Linaclotide acetate, Lumiracoxib, LY-517717; Malaria vaccine, MAS-063D, Meningitis B vaccine, Mepolizumab, Methylnaltrexone bromide, Micafungin sodium, MK-0822A, Morphine glucuronide, Morphine hydrochloride, Mycophenolic acid sodium salt; Natalizumab, Nesiritide, Norelgestromin/ethinyl estradiol, NT-201; Oblimersen sodium, Olmesartan medoxomil, Olmesartan medoxomil/hydrochlorothiazide, Omalizumab, Otamixaban; Paclitaxel nanoparticles, Panitumumab, Panobinostat, Parathyroid hormone (human recombinant), Parecoxib sodium, Pegfilgrastim, Peginterferon alfa-2a, Peginterferon alfa-2b, Pegvisomant, PI-88, Pimecrolimus, Pneumococcal 7-valent conjugate vaccine, Pneumococcal 9-valent conjugate vaccine, Pneumococcal conjugate vaccine, Poloxamer-188, Prasugrel, Pregabalin, Prulifloxacin; R-109339, Ramipril/amlodipine, Ranolazine, Rasburicase, rHA influenza vaccine, Ro-50-3821, Rosuvastatin calcium, Rotavirus vaccine, Rotigotine, Ruboxistaurin mesilate hydrate; Satavaptan, SC-75416, Solifenacin succinate, Sorafenib, Sugammadex sodium, Sunitinib malate, Synthetic conjugated estrogens B; Tadalafil, Talnetant, Taxus, Tegaserod maleate, Telbivudine, Temsirolimus, Tenofovir disoproxil fumarate, Tetomilast, Tiotropium bromide, Tipifarnib, Tofimilast, Tremelimumab, Trimethoprim; Udenafil, Urocortin 2; Valdecoxib, Vernakalant hydrochloride; XP-828L.

View Article and Find Full Text PDF

A sensitive bioanalytical method for the measurement of two major circulating metabolites of duloxetine [4-hydroxy duloxetine glucuronide (LY550408) and 5-hydroxy-6-methoxy duloxetine sulfate (LY581920)] in plasma is reported. This method produced acceptable precision and accuracy over the validation range of 1-1000 ng/mL. Several issues had to be addressed in order to develop an LC/MS/MS assay for these metabolites.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!