Recent electrophysiological evidence suggested the existence of a human magnetic sense, but the kind of dynamical law that governed the stimulus-response relationship was not established. We tested the hypothesis that brain potentials evoked by the onset of a weak, low-frequency magnetic field were nonlinearly related to the stimulus. A field of 1G, 60 Hz was applied for 2s, with a 5s inter-stimulus period, and brain potentials were recorded from occipital electrodes in eight subjects, each of whom were measured twice, with at least 1 week between measurements. The recorded signals were subjected to nonlinear (recurrence analysis) and linear (time averaging) analyses. Using recurrence analysis, magnetosensory evoked potentials (MEPs) were detected in each subject in both the initial and replicate studies, with one exception. All MEPs exhibited the expected latency but differed in dynamical characteristics, indicating that they were nonlinearly related to the stimulus. MEPs were not detected using time averaging, thereby further confirming their nonlinearity. Evolutionarily conditioned structures that help mediate linear field-transduction in lower life forms may be expressed and functionally utilized in humans, but in a role where they facilitate vulnerability to man-made environmental fields.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.neulet.2007.02.046DOI Listing

Publication Analysis

Top Keywords

low-frequency magnetic
8
brain potentials
8
nonlinearly stimulus
8
recurrence analysis
8
time averaging
8
meps detected
8
nonlinear eeg
4
eeg activation
4
activation evoked
4
evoked low-strength
4

Similar Publications

Simulation Research on Low-Frequency Magnetic Noise in Fe-Based Nanocrystalline Magnetic Shields.

Materials (Basel)

January 2025

School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China.

Depending on high permeability, high Curie temperature, and low eddy current loss noise, nanocrystalline alloys, as the innermost layer, exhibit great potential in the construction of cylindrical magnetic shielding systems with a high shielding coefficient and low magnetic noise. This study compares a magnetic noise of 1 Hz, simulated by the finite element method (FEM), of a cylindrical nanocrystalline magnetic shield with different structural parameters based on the measured initial permeability of commercial Fe-based nanocrystalline (1K107). The simulated results demonstrate that the magnetic noise is irrelevant to the pump and probe hole diameter.

View Article and Find Full Text PDF

Background: Neurovascular coupling (NVC), as indicated by a comprehensive analysis of the amplitude of low-frequency fluctuation (ALFF) and cerebral blood flow (CBF), provides mechanistic insights into neurological disorders. Patients undergoing peritoneal dialysis (PD) and hemodialysis (HD) often face cognitive impairment, the causes of which are not fully understood.

Methods: ALFF was derived from functional magnetic resonance imaging, and CBF was quantified using arterial spin labeling in a cohort comprising 58 patients with PD, 60 patients with HD and 62 healthy controls.

View Article and Find Full Text PDF

Bridging animal models and humans: neuroimaging as intermediate phenotypes linking genetic or stress factors to anhedonia.

BMC Med

January 2025

Early Intervention Unit, Department of Psychiatry, Affiliated Nanjing Brain Hospital, Nanjing Medical University, 264 Guangzhou Street, Nanjing, China.

Background: Intermediate phenotypes, such as characteristic neuroimaging patterns, offer unique insights into the genetic and stress-related underpinnings of neuropsychiatric disorders like depression. This study aimed to identify neuroimaging intermediate phenotypes associated with depression, bridging etiological factors to behavioral manifestations and connecting insights from animal models to diverse clinical populations.

Methods: We analyzed datasets from both rodents and humans.

View Article and Find Full Text PDF

Background And Objectives: Recently, reduction of transcallosal inhibition by contralateral navigated repetitive transcranial magnetic stimulation (nrTMS) improved neurorehabilitation of glioma patients with new postoperative paresis. This multicentric study examines the effect of postoperative nrTMS in brain tumor patients to treat surgery-related upper extremity paresis.

Methods: This is a secondary analysis of two randomized and three one-arm studies in brain tumor patients with new/progressive postoperative paresis.

View Article and Find Full Text PDF

Integration of Asymmetric Multi-Path Hollow Structure and Multiple Heterogeneous Interfaces in FeO@C@NiO Nanoprisms Enabling Ultra-Low and Broadband Absorption.

Small

January 2025

Key Laboratory of Aerospace Materials and Performance (Ministry of Education) School of Materials Science and Engineering, Beihang University, No.37 Xueyuan Road, Beijing, 100191, P. R. China.

A reasonable construction of hollow structures to obtain high-performance absorbers is widely studied, but it is still a challenge to select suitable materials to improve the low-frequency attenuation performance. Here, the FeO@C@NiO nanoprisms with unique tip shapes, asymmetric multi-path hollow cavity, and core-shell heteroepitaxy structure are designed and synthesized based on anisotropy and intrinsic physical characteristics. Impressively, by changing the load of NiO, the composites achieve strong absorption, broadband, low-frequency absorption: the reflection loss of -55.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!