A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Novel microneutralization assay for HCMV using automated data collection and analysis. | LitMetric

In addition to being sensitive and specific, an assay for the assessment of neutralizing antibody activity from clinical trial samples must be amenable to automation for use in high-volume screening. To that effect, we developed a 96-well microplate assay for the measurement of HCMV-neutralizing activity in human sera using the HCMV-permissive human cell line HEL-299 and the laboratory strain of HCMV AD169. The degree to which neutralizing antibodies diminish HCMV infection of cells in the assay is determined by quantifying the nuclei of infected cells based on expression of the 72 kDa IE1 viral protein. Nuclear IE1 is visualized using a highly sensitive immunoperoxidase staining and the stained nuclei are counted using an automated ELISPOT analyzer. The use of Half Area 96-well microplates, with wells in which the surface area of the well bottom is half the area of a standard 96-well microplate plate, improves signal detection compared with standard microplates and economizes on the usage of indicator cells, virus, and reagents. The staining process was also streamlined by using a microplate washer and data analysis was simplified and accelerated by employing a software program that automatically plots neutralization curves and determines NT(50) values using 4-PL curve fitting. The optimized assay is not only fast and convenient, but also specific, sensitive, precise and reproducible and thus has the characteristics necessary for use in measuring HCMV-neutralizing activity in the sera of vaccine trial subjects such as the recipients of Vical's HCMV pDNA vaccine candidates.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1933494PMC
http://dx.doi.org/10.1016/j.jim.2007.02.001DOI Listing

Publication Analysis

Top Keywords

96-well microplate
8
hcmv-neutralizing activity
8
half area
8
assay
5
novel microneutralization
4
microneutralization assay
4
hcmv
4
assay hcmv
4
hcmv automated
4
automated data
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!