Duty cycle dependence of ultrasound enhanced thrombolysis in a human clot model.

Ultrasound Med Biol

Department of Emergency Medicine, College of Medicine, University of Cincinnati, Cincinnati, OH 45267, USA.

Published: April 2007

Combined ultrasound and tissue plasminogen activator (rt-PA) therapy, or ultrasound enhanced thrombolysis (UET), has been shown to improve recanalization in patients with acute ischemic stroke. We measured the effect of ultrasound duty cycle on the lytic efficacy of 120 kHz UET in an in vitro human clot model. The hypothesis was that an increase in duty cycle increases rt-PA lytic efficacy. Human whole blood clots were exposed to 120-kHz ultrasound and rt-PA for 30 min in human plasma. The duty cycle ranged from 0% to 80%, where 0% represents sham exposure. Clot lytic rate was measured by recording the clot width over time. The clot width after 30 min exposure to rt-PA and ultrasound decreases with increasing duty cycle. The initial lytic rate increased linearly with duty cycle.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1995459PMC
http://dx.doi.org/10.1016/j.ultrasmedbio.2006.10.010DOI Listing

Publication Analysis

Top Keywords

duty cycle
24
ultrasound enhanced
8
enhanced thrombolysis
8
human clot
8
clot model
8
lytic efficacy
8
lytic rate
8
clot width
8
duty
6
ultrasound
6

Similar Publications