Introduction: Percutaneous nephrostomy has traditionally been performed with the patient in the prone position, probably to reduce the risk of injury to adjacent visceral organs, particularly the colon. The prone position, however, is associated with disadvantages such as patient discomfort and circulatory and ventilatory difficulties, particularly in obese patients. We describe a technique of percutaneous nephrostomy with the patient in the supine anterolateral position using local anesthesia, ultrasound-guided puncture, and fluoroscopy-controlled placement.
Technical Considerations: The supine anterolateral position was obtained by placing towels under the ipsilateral shoulder and gluteus to elevate the flank approximately 30 degrees, thus providing enough space for ultrasound scanning and ultrasound-guided puncture of the collecting system. The ipsilateral arm was placed over the thorax, and the contralateral arm was used for intravenous perfusion. The ipsilateral leg was flexed slightly, and the contralateral leg was flexed and abducted so that its lateral aspect lay on the table, providing adequate space in case of concomitant transurethral manipulation. In this supine position, the colon falls anteromedially and thus well apart from the puncture paths. In contrast, in the prone position, it is pushed against the lateral surface of the kidney in the way of possible puncture paths.
Conclusions: Our experience with 12 consecutive patients showed this technique to be easy, safe, and effective and to prevent the discomfort and ventilation difficulties of the prone position, particularly in obese patients or those in poor general condition or with respiratory problems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.urology.2007.01.020 | DOI Listing |
Clin Cardiol
January 2025
Second Department of Internal Medicine, University of Toyama, Toyama, Japan.
Sci Rep
January 2025
Haohua Hongqingliang Mining Company, Ltd, Ordos, 014300, Inner Mongolia, China.
Caving mining in extra-thick coal seams induces large-scale overburden movement, leading to more intense fracture processes in key strata, more significant surface subsidence, and frequent dynamic disasters in mines. This study, using the N34-2 caving face of the 17th coal seam at Junde Mine as a case study, aims to investigate the time-varying linkage mechanism between surface subsidence, microseismic characteristics, and fracture scales of the overburden's key strata under such mining conditions. Based on Timoshenko's theory, a bearing fracture mode for the overburden's key strata is proposed, and corresponding fracture criteria are established.
View Article and Find Full Text PDFPlast Reconstr Surg Glob Open
January 2025
From the Division of Plastic Surgery, Mayo Clinic, Phoenix, AZ.
Background: Vertebral body defects pose a significant challenge in spinal reconstructive surgery. Compression fractures of the vertebral corpus are typically treated with vertebral augmentation procedures. There are significant risks associated with the introduction of foreign material in the spine, including infection and pseudarthrosis.
View Article and Find Full Text PDFCureus
December 2024
Department of Radiological Technology, Fujieda Municipal General Hospital, Fujieda, JPN.
Purpose This study aimed to clarify which positions are beneficial for patients with pathological lung diseases, such as acute respiratory distress syndrome, by obtaining lung ventilation and deformable vector field (DVF) images using Deformable Image Registration (DIR). Methods Thirteen healthy volunteers (5 female, 8 male) provided informed consent to participate to observe changes in normal lungs. DIR imaging was processed using the B-spline algorithm to obtain BH-CTVI (inhale, exhale) in four body positions (supine, prone, right lateral, left lateral) using DIR-based breath-hold CT ventilation imaging (BH-CTVI).
View Article and Find Full Text PDFBiol Rev Camb Philos Soc
January 2025
Wildlife Observatory of Australia (WildObs), Queensland Cyber Infrastructure Foundation (QCIF), Brisbane, Queensland, 4072, Australia.
Camera traps are widely used in wildlife research and monitoring, so it is imperative to understand their strengths, limitations, and potential for increasing impact. We investigated a decade of use of wildlife cameras (2012-2022) with a case study on Australian terrestrial vertebrates using a multifaceted approach. We (i) synthesised information from a literature review; (ii) conducted an online questionnaire of 132 professionals; (iii) hosted an in-person workshop of 28 leading experts representing academia, non-governmental organisations (NGOs), and government; and (iv) mapped camera trap usage based on all sources.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!