Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jtcvs.2006.08.105 | DOI Listing |
Gen Thorac Cardiovasc Surg Cases
January 2025
Osaka Metropolitan University Graduate School of Medicine, 1-4-3, Asahimachi, Abeno-Ku, Osaka, 545-8585, Japan.
Background: Repair of the regurgitant bicuspid aortic valve is an attractive alternative to valve replacement. Although good long-term outcomes have been reported, postoperative aortic stenosis remains a major late cause of repair failure in bicuspid aortic valves. Sinus plication is effective for creating a more symmetrical commissural angle, leading to a decrease in the mean transvalvular pressure gradient.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Cardiac Surgery, Medical University Innsbruck, Anichstrasse 35, A-6020 Innsbruck, Austria.
Background: Traumatic tricuspid valve regurgitation is a rare condition related to blunt chest trauma. In the early phase, the patients may remain asymptomatic. Progressive tricuspid regurgitation leads to the development of symptoms thereafter.
View Article and Find Full Text PDFKyobu Geka
October 2024
Department of Cardiovascular Surgery, Nakadori General Hospital, Akita, Japan.
Left atrial appendage closure is widely performed in cardiac surgery to prevent intracardiac thrombus in patients with atrial fibrillation. Herein, we report the surgical case of an 80-year-old man whose left atrial appendage became aneurysmic long after undergoing suture exclusion. At the age of 67, he underwent mitral valve annuloplasty and left atrial appendage suture exclusion for mitral regurgitation and chronic atrial fibrillation at our institution.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
February 2025
Institution of Biomechanics, Department of Aeronautics and Astronautics, Fudan University, Shanghai, China; Institution of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, China. Electronic address:
Bicuspid aortic valve (BAV) patients are more predisposed to aortic regurgitation. Annuloplasty is a crucial therapeutic intervention, however, determining its ideal size remains a clinical challenge. This study aims to quantify the effects of varying annuloplasty sizes on treating BAV regurgitation, providing optimal size range for effective treatment while avoiding complications.
View Article and Find Full Text PDFEur J Cardiothorac Surg
October 2024
Department of Cardiothoracic Surgery, Augsburg University Hospital, Augsburg, Germany.
We present a modified technique of Hemispherical Aortic Annuloplasty Reconstructive Technology (HAART) 200 annuloplasty ring implantation in bicuspid aortic valve morphology by external fixation of the looping sutures to avoid common complications associated with the original implantation technique. Preliminary results are promising and should be confirmed in subsequent multicentre studies.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!